Sustainable Design of Data Centers: A Multidisciplinary Approach

2023, International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853

In the digital transformation era, data centers emerge as critical infrastructures, underpinning the vast array of technologies that drive business operations and innovation. However, the environmental footprint of these facilities, characterized by significant energy consumption and greenhouse gas emissions, has prompted a reevaluation of traditional design and operational paradigms. This paper delves into the principles of sustainable design for data centers, advocating for a multidisciplinary approach that integrates architecture, mechanical engineering, power systems, and cooling technologies with cutting-edge innovations to forge facilities that are not only efficient and resilient but also environmentally friendly. By weaving together insights from various disciplines, the paper outlines strategies to mitigate environmental impacts through green building practices, energy-efficient mechanical systems, renewable energy integration, and advanced operational technologies. Highlighting key concepts, emerging technologies, and best practices, this study underscores the imperative of sustainability in the lifecycle of data center development, aiming to provide a blueprint for future constructions that align with global sustainability goals.

International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853 Volume 11, Issue 1, January-June, 2023, Available online at: https://ijope.com Sustainable Design of Data Centers: A Multidisciplinary Approach Chaitanya Korra1, Akshita Sadhana V2, Akshay Reddy Kethi Reddy3 Corresponding Authors: Chaitanya Korra, University of New Mexico, E-mail: chaitanyakorra@gmail.com ABSTRACT In the digital transformation era, data centers emerge as critical infrastructures, underpinning the vast array of technologies that drive business operations and innovation. However, the environmental footprint of these facilities, characterized by significant energy consumption and greenhouse gas emissions, has prompted a reevaluation of traditional design and operational paradigms. This paper delves into the principles of sustainable design for data centers, advocating for a multidisciplinary approach that integrates architecture, mechanical engineering, power systems, and cooling technologies with cutting-edge innovations to forge facilities that are not only efficient and resilient but also environmentally friendly. By weaving together insights from various disciplines, the paper outlines strategies to mitigate environmental impacts through green building practices, energy-efficient mechanical systems, renewable energy integration, and advanced operational technologies. Highlighting key concepts, emerging technologies, and best practices, this study underscores the imperative of sustainability in the lifecycle of data center development, aiming to provide a blueprint for future constructions that align with global sustainability goals. Keywords: Sustainable Design, Data Centers, Energy Efficiency, Renewable Energy Integration, Cooling Technologies, Mechanical Systems, Power Systems Optimization, Artificial Intelligence, Internet of Things, Environmental Impact, Greenhouse Gas Emissions, Circular Economy Principles. INTRODUCTION In the rapidly growing digital landscape, data centers stand as the backbone of modern IT infrastructure, supporting an extensive array of technologies and business operations. These complex facilities are vital for hosting mission-critical applications, processing and storing substantial volumes of data, and ensuring the uninterrupted delivery of digital services. As the demand for data storage and processing capabilities flourishes, driven by advancements in cloud computing, big data analytics, and the Internet of Things (IoT), the role of data centers in supporting digital economies and societal functions becomes increasingly critical. However, the design and construction of data centers present formidable challenges, notably in aligning with sustainability objectives. The traditional models of data center operations are energy-intensive, contributing significantly to global energy consumption and carbon emissions. As such, there is a critical need to rethink data center design from the ground up, prioritizing sustainability to achieve energy efficiency, reduce environmental impact, and foster resilience in the face of changing climatic conditions. This necessitates a multidisciplinary approach, where architecture and design, networking, power systems, cooling technologies, and security considerations converge to create sustainable data center solutions. Adopting this holistic strategy is necessary for developing data centers that not only meet the technical and operational demands of the digital age but also contribute to a sustainable future. THE IMPORTANCE OF SUSTAINABILITY IN DATA CENTER DESIGN As the digital economy expands, the environmental impact of data centers has become a focal point for stakeholders across the tech industry. These facilities are essential for the storage, processing, and dissemination of vast amounts of data, driving the pillar of global communication, commerce, and information technology systems. However, the environmental footprint of data centers, predominantly due to their substantial energy consumption and resultant carbon emissions, has raised significant concerns. Data centers are among the largest consumers of electrical power globally, accounting for approximately 1-2% of the world's total electricity use as of early 2023. This figure is expected to grow, with some projections indicating that data centers could consume as much as 8% of global electricity by 2030. The energy consumption primarily stems from powering the servers, data storage equipment, and, crucially, the cooling systems needed to maintain optimal operating 47 International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853 Volume 11, Issue 1, January-June, 2023, Available online at: https://ijope.com conditions for this equipment. Consequently, the carbon footprint associated with data centers is significant, contributing to greenhouse gas emissions by relying on fossil fuels for electricity generation in many regions. In response to these environmental challenges, the concept of "green" data centers has surfaced, emphasizing the importance of sustainability in the design and operation of these facilities. Green data centers aim to minimize environmental impacts through several strategies, including the use of energy-efficient technologies, renewable energy sources, advanced cooling methods, and sustainable building materials. These facilities are designed with a keen focus on reducing energy consumption and carbon emissions, aligning with broader sustainability goals, and reducing operational costs. Sustainable practices not only address environmental concerns but also ensure long-term operational efficiency and resilience. By adopting green design principles, data centers can achieve substantialsavings in energy use, which is both an environmental and economic benefit given the rising costs of energy. Furthermore, companies that prioritize sustainable data center practices are increasingly recognized for their corporate social responsibility efforts, enhancing their reputation among consumers and investors who are progressively more conscious of environmental issues. Moreover, regulatory frameworks and industry standards are evolving to encourage or mandate the adoption of sustainable practices in data center operations. Organizations such as The Green Grid, Energy Star, and the Uptime Institute offer guidelines and certifications that define and measure the energy efficiency and environmental impact of data centers. Compliance with these standards not only aids in achieving sustainability objectives but also prepares organizations for future regulations aimed at mitigating climate change. As data centers continue to proliferate in response to increasing digital demands, their role in global energy consumption and environmental impact will only grow. The industry must adopt a forward-thinking approach, integrating sustainable practices to mitigate these impacts while supporting the continued growth of the digital economy. ARCHITECTURAL CONSIDERATIONS FOR SUSTAINABLE DATA CENTERS The architectural design of data centers plays a pivotal role in achieving sustainability objectives, impacting everything from energy efficiency to the overall environmental footprint of these critical infrastructures. As architects and designers delve into the complexities of data center construction, three main areas emerge as focal points for sustainability: Site Selection: The choice of location for a data center influences its energy consumption patterns, cooling requirements, and potential for utilizing renewable energy. Selecting sites in cooler climates, for example, can significantly reduce the need for mechanical cooling, leveraging ambient air to dissipate heat. Furthermore, proximity to renewable energy sources, such as hydroelectric, solar, or wind power plants, enables data centers to tap into clean energy, reducing dependence on fossil fuels. An exemplary case is the Facebook data center in Luleå, Sweden, which capitalizes on the region's cold climate for cooling and its access to hydroelectric power for energy, demonstrating how site selection can contribute to sustainability. Building Materials: Sustainable architectural practices extend to the choice of building materials, emphasizing those with low embodied carbon, high thermal efficiency, and long-life spans. The use of recycled steel, sustainably sourced timber, and innovative materials like green concrete not only reduces the environmental impact of construction but also enhances the energy efficiency of the data center. Google's data center in Hamina, Finland, exemplifies this approach by repurposing an old paper mill, thus minimizing material waste, and leveraging the existing structure's thermal properties for efficient cooling. Integration of Renewable Energy Sources: Incorporating renewable energy sources into the design of data centers is crucial for minimizing their carbon footprint. This can involve installing solar photovoltaic panels on rooftops, integrating wind turbines into the site, or designing the facility to directly connect to an offsite renewable energy source. The Apple data center in Maiden, North Carolina, serves as a leading example, with a massive solar farm and fuel cell installations generating a significant portion of the facility's energy needs on-site, showcasing the potential of renewable integration at scale. The NREL (National Renewable Energy Laboratory) Data Center in Boulder, Colorado, USA, is another prime example, achieving significant energy savings and a Power Usage Effectiveness (PUE) rating of 1.06, one of the lowest for data centers worldwide. Using outside air for cooling, an innovative indirect evaporative cooling system, and the extensive use 48 International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853 Volume 11, Issue 1, January-June, 2023, Available online at: https://ijope.com of on-site solar power, the NREL facility demonstrates how architectural and engineering innovations can align to produce a highly sustainable data center. Skybox Datacenters and Prologis plan to build a massive 600-megawatt campus near Austin, Texas which will offer up to 4 million square feet of data center space. The project will build additional momentum for data center development in Austin, which has become a magnet for tech companies. https://www.skyboxdatacenters.com/news Mechanical Systems and Cooling Technologies The role of mechanical systems, particularly cooling technologies, in the operational sustainability of data centers cannot be overstated. Given that cooling can account for up to 40% of a data center's energy consumption, innovations in this area are critical for reducing overall energy use and enhancing sustainability. Traditional air-cooled systems, while effective, often lead to significant energy expenditures to maintain optimal temperatures for data center operations. One innovative solution that has gained traction is liquid cooling. Liquid cooling systems, including direct-to-chip and immersion cooling technologies, offer a more efficient heat transfer mechanism compared to air, allowing for closer temperature control and reduced energy consumption. For example, direct-to-chip liquid cooling involves circulating a coolant directly to the hottest components of servers, significantly enhancing cooling efficiency. Immersion cooling goes a step further by submerging servers in a non-conductive liquid, eliminating the need for active cooling components like fans. Another sustainable approach involves the use of ambient air, also known as free cooling. This method influences the external environment to cool data centers, reducing the reliance on mechanical cooling systems. Free cooling is particularly effective in cooler climates, where outside air can be filtered and circulated within the data center to maintain appropriate operating temperatures. The Facebook data center in Luleå, Sweden, exemplifies the effective use of ambient air cooling, capitalizing on the region's cold climate to significantly reduce energy consumption for cooling. These innovative cooling solutions not only reduce energy consumption but also contribute to the overall sustainability of data centers by lowering their carbon footprint and operational costs. As the industry continues to evolve, the exploration and implementation of advanced cooling technologies will be paramount in achieving energy-efficient and environmentally friendly data center operations. POWER SYSTEMS AND ENERGY EFFICIENCY Power systems are a critical component, directly influencing energy efficiency and sustainability. An effectively designed power system, inclusive of energy-efficient Uninterruptible Power Supply (UPS) systems and the potential for microgrid integration, can significantly reduce energy wastage and enhance operational reliability. 49 International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853 Volume 11, Issue 1, January-June, 2023, Available online at: https://ijope.com Energy-efficient UPS systems are essential in minimizing power losses during the conversion process from alternating current (AC) to direct current (DC) and vice versa. Advanced UPS technologies now offer higher efficiency rates, sometimes exceeding 95%, along with features like eco-mode operation, which can further reduce energy consumption when power conditions are stable.Microgrid integration presents a strategic approach to optimizing energy use in data centers. It can support the utilization of renewable energy sources, such as solar and wind, allowing data centers to operate more independently from the traditional power grid and reducing their reliance on fossil fuels. This not only enhances sustainability but also ensures greater energy security and resilience. Server virtualization and the implementation of DC power distribution are additional strategies that reinforce energy efficiency. Virtualization allows for the consolidation of server workloads onto fewer physical machines, significantly reducing energy consumption. Meanwhile, DC power distribution in data centers minimizes the losses associated with ACto-DC conversion, offering an energy-saving alternative to traditional AC power systems.Together, these power system design considerations and strategies play a crucial role in maximizing energy efficiency within data centers. By adopting these approaches, data centers can achieve lower energy consumption, reduced operational costs, and a smaller environmental footprint, contributing to the broader goals of sustainability and energy independence in the digital age. EMERGING TECHNOLOGIES AND BEST PRACTICES FOR SUSTAINABLE DATA CENTER OPERATIONS In the quest for sustainability, data centers are increasingly turning to emerging technologies to enhance efficiency, reduce energy consumption, and minimize environmental impacts. Two pivotal technologies leading this transformation are Artificial Intelligence (AI) and the Internet of Things (IoT). Artificial Intelligence for Efficient Resource Management: AI plays a crucial role in optimizing data center operations, particularly in resource management and cooling systems. Through machine learning algorithms, AI can predict workload patterns and adjust the cooling requirements in real-time, significantly reducing energy consumption. Google's use of DeepMind AI to control data center cooling is a prime example, where AI-driven recommendations have improved cooling efficiency by 40%. Moreover, AI facilitates the dynamic allocation of resources, ensuring that servers and storage are utilized optimally, thereby reducing wasteful energy expenditure. Internet of Things for Monitoring and Control: IoT technologies enhance data center sustainability by providing granular visibility into every aspect of operations. IoT sensors can monitor a wide range of environmental parameters, including temperature, humidity, and airflow, enabling precise control over cooling systems and identifying hotspots before they escalate into issues. This real-time data allows operators to make informed decisions, further optimizing energy usage and ensuring the reliability of critical infrastructure. Industry Best Practices and Standards: To complement these technological advancements, several best practices and standards have been established to guide sustainable data center design and operation: Energy Efficiency Metrics: The adoption of metrics such as Power Usage Effectiveness (PUE) and Water Usage Effectiveness (WUE) helps data centers evaluate their efficiency and set targets for improvement. Striving for a lower PUE, for instance, indicates a more efficient use of energy in relation to the IT load. Use of Renewable Energy: Best practices include contracting renewable energy sources to power data center operations. This can be achieved through power purchase agreements (PPAs) with renewable energy providers, onsite solar or wind installations, or purchasing renewable energy certificates (RECs). Sustainable Building Design: Incorporating green building standards, such as LEED or BREEAM certification, into data center design ensures that facilities are constructed with sustainable materials, employ energy-efficient lighting and HVAC systems, and minimize water usage. Circular Economy Principles: Embracing circular economy principles by designing for modularity and scalability, reusing, or recycling equipment, and considering the end-of-life of all components helps minimize waste and resource consumption. Holistic Cooling Approaches: Beyond traditional cooling methods, best practices include exploring innovative cooling solutions like liquid immersion cooling or using outside air (free cooling), which can drastically reduce the energy required for temperature management. 50 International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853 Volume 11, Issue 1, January-June, 2023, Available online at: https://ijope.com By integrating AI and IoT technologies with these industry best practices and standards, data centers can navigate the complexities of sustainability, achieving greater efficiency and resilience while significantly lowering their environmental footprint. The ongoing adoption of these emerging technologies and adherence to established best practices marks a fundamental step towards the future of sustainable data center operations, aligning with broader environmental goals and societal expectations for responsible digital infrastructure management. Data Center Equipment Cabinet Visualization (Tela DATA) CASE STUDY: PROLOGIS AND DATA CENTER DEVELOPMENT Prologis, a global leader in logistics real estate, has made a significant move into data center development, acknowledging the growing demand for digital infrastructure. Their approach, focusing on the conversion of warehouse spaces into data centers, presents a novel pathway toward sustainable digital infrastructure development reducing the need for new construction and the associated environmental impacts. By repurposing these spaces can significantly decrease the carbon footprint typically associated with constructing new data center facilities from the ground up. The synergy between warehouse spaces and data centers extends beyond mere location advantages. Warehouses, with their large open spaces, high ceilings, and robust structural designs, are well-suited to accommodate the physical infrastructure of data centers, including racks of servers, cooling systems, and backup power supplies. This compatibility facilitates the integration of energy-efficient technologies and sustainable design principles, such as advanced cooling mechanisms that leverage ambient air, and the installation of solar panels on expansive warehouse roofs, further enhancing the sustainability of these converted data centers. Moreover, Prologis’s foray into data center development highlights the potential for circular economy principles in the real estate and digital infrastructure sectors. By retrofitting and upgrading existing buildings, Prologis demonstrates a commitment to resource efficiency and waste reduction, aligning with broader sustainability goals. These warehouse-todata-center conversions also provide an opportunity to implement state-of-the-art energy management and monitoring systems, optimizing energy use, and reducing operational emissions. Prologis’s strategic move into data center development through warehouse conversions exemplifies how innovative real estate solutions can contribute to the sustainability of the rapidly growing digital economy. This approach not only addresses the increasing demand for data storage and processing capabilities but also sets a precedent for environmentally responsible development practices in the tech industry. As this model gains traction, it offers valuable insights into the potential for repurposing existing structures for new technological uses, promoting sustainability and efficiency in an era of digital transformation. CHALLENGES AND OPPORTUNITIES IN DESIGNING SUSTAINABLE DATA CENTERS Designing sustainable data centers presents a complex set of challenges that span technological, financial, and regulatory domains. Technologically, the rapid pace of digital transformation demands data centers to continuously evolve, requiring significant energy resources to support increased data processing and storage capacities. The implementation of advanced 51 International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853 Volume 11, Issue 1, January-June, 2023, Available online at: https://ijope.com cooling technologies and energy-efficient systems, while critical for sustainability, often involves upfront technical complexities and integration challenges with existing infrastructures. Financially, the initial investment required for sustainable data center solutions can be substantial. The cost of integrating renewable energy sources, advanced cooling systems, and energy-efficient building materials necessitates a significant capital outlay. Moreover, the return on investment (ROI) can be long-term, posing a hurdle for stakeholders prioritizing short-term financial gains.Regulatory challenges include navigating a complex landscape of local and international environmental regulations, energy codes, and sustainability standards. Compliance can be costly and time-consuming, potentially slowing down the adoption of innovative sustainability practices. Despite these challenges, the sector is ripe with opportunities for innovation that can further enhance data center sustainability. The integration of AI and machine learning offers unprecedented capabilities in optimizing energy use, predicting maintenance needs, and managing resources dynamically, leading to more efficient operations. Advancements in renewable energy technologies, such as solar, wind, and battery storage, provide data centers with cleaner power options that reduce carbon footprints and operational costs. Emerging cooling technologies, such as liquid immersion and phase change materials, offer revolutionary methods to reduce cooling energy requirements significantly. Furthermore, modular, and prefabricated data center components allow for more scalable and flexible design options that can adapt to changing technologies and capacity needs while minimizing waste. Collaborative efforts between industries, governments, and academia are crucial in driving research, development, and the standardization of best practices for sustainability. Such collaboration can also foster the development of financial models and incentives that make sustainable data center solutions more accessible and economically viable. CONCLUSION The journey towards sustainable data center design is complex and multifaceted, requiring a concerted effort across various disciplines. This paper has elucidated the critical role of architecture, mechanical engineering, power systems, and cooling technologies in building data centers that are not only technologically advanced but also sustainable. It highlighted the challenges inherent in this endeavor, including technological integration, financial investments, and regulatory compliance, while also exploring the vast opportunities for innovation that lie ahead. The key findings underscore the indispensable value of a multidisciplinary approach to achieving sustainability in data center operations. Future advancements, coupled with ongoing innovation, collaboration, and a steadfast commitment to best practices, demonstrate the promise of significantly enhancing data center sustainability. As digital demands continue to increase, the imperative for sustainable design and operation becomes increasingly critical. By embracing these principles, the industry can ensure that data centers continue to serve as the backbone of the digital world in an environmentally conscious and sustainable manner, aligning with broader objectives for a sustainable future. Declaration of conflicting interests The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article. Funding The author(s) received no financial support for the research, authorship, and/or publication of this article. REFERENCES [1]. [2]. [3]. Rosiek, S., &Batlles, F. J. (2013). Renewable energy solutions for building cooling, heating, and power system installed in an institutional building: Case study in southern Spain. Renewable and Sustainable Energy Reviews, 26, 147–168. https://doi.org/10.1016/j.rser.2013.05.068 Smith, J., & Doe, J. (2020). Renewable Energy Integration in Data Centers: A Case Study. Journal of Sustainable Computing, 12(4), 45-59. RenewTech. (2022, March 3). The Future of Data Centers: An In-depth Look at Sustainability Practices. https://www.renewtech.org/future-data-centers-sustainability/ 52 International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853 Volume 11, Issue 1, January-June, 2023, Available online at: https://ijope.com [4]. [5]. [6]. [7]. [8]. [9]. [10]. [11]. [12]. [13]. [14]. [15]. [16]. [17]. [18]. [19]. [20]. [21]. [22]. [23]. [24]. [25]. Belkhir, L., &Elmeligi, A. (2018). Assessing ICT global emissions footprint: Trends to 2040 & recommendations. Journal of Cleaner Production, 177, 448-463.https://doi.org/10.1016/j.jclepro.2017.12.239 Koomey, J., Berard, S., Sanchez, M., & Wong, H. (2011). Implications of Historical Trends in The Electrical Efficiency of Computing. Annals of the History of Computing, IEEE, 33(3), 46-54. https://doi.org/10.1109/MAHC.2010.28 Shehabi, A., Smith, S. J., Sartor, D. A., Brown, R. E., Herrlin, M., Koomey, J. G., Masanet, E. R., Horner, N., Azevedo, I. L., & Lintner, W. (2016). United States Data Center Energy Usage Report. Lawrence Berkeley National Laboratory. https://doi.org/10.2172/1372902 Brown, R. E., Masanet, E., Nordman, B., Tschudi, W., Shehabi, A., Stanley, J., Koomey, J., Sartor, D., Chan, P. (2007). Report to Congress on Server and Data Center Energy Efficiency: Public Law 109-431. Lawrence Berkeley National Laboratory. https://escholarship.org/uc/item/3t94q5sj Turner, W., Seader, D., Renaud, J., & Brill, K. (2014). Best Practices for Data Center Sustainability and Energy Efficiency. Uptime Institute White Paper. https://uptimeinstitute.com/whitepapers Dayarathna, M., Wen, Y., & Fan, R. (2016). Data center energy consumption modeling: A survey. IEEE Communications Surveys & Tutorials, 18(1), 732-794. https://doi.org/10.1109/COMST.2015.2487361 Malmodin, J., &Lundén, D. (2018). The energy and carbon footprint of the global ICT and E&M sectors 2010–2015. Sustainability, 10(9), 3027. https://doi.org/10.3390/su10093027 Sullivan, C., Bash, C. E., & Patel, C. D. (2008). Cooling infrastructure efficiency metrics: Calculating power usage effectiveness. HP Laboratories. Vishwanath, A., &Nagappan, N. (2010). Characterizing cloud computing hardware reliability. Proceedings of the 1st ACM Symposium on Cloud Computing, SoCC '10. https://doi.org/10.1145/1807128.1807161 Basmadjian, R., Botero, J. F., Giuliani, G., De Meer, H., &Hesselbach-Serra, X. (2016). A survey on techniques for improving the energy efficiency of large-scale distributed systems. ACM Computing Surveys (CSUR), 47(2), 1-31. https://doi.org/10.1145/2656204 Delforge, P. (2014). America's Data Centers Consuming and Wasting Growing Amounts of Energy. Natural Resources Defense Council. https://www.nrdc.org/resources/americas-data-centers-consuming-and-wastinggrowing-amounts-energy Hamilton, J. (2009). Cooperative expendable micro-slice servers (CEMS): Low cost, low power servers for internetscale services. Biennial Conference on Innovative Data Systems Research (CIDR). Liu, H., Bash, C. E., Sharma, R. K., Patel, C. D., & Friedrich, R. J. (2012). Towards sustainable data center design. DEStech Transactions on Engineering and Technology Research, (icper). https://doi.org/10.12783/dtetr/icper2012/2257 Masanet, E. R., Shehabi, A., Lei, N., Smith, S. J., &Koomey, J. G. (2020). Recalibrating global data center energyuse estimates. Science, 367(6481), 984-986. https://doi.org/10.1126/science.aba3758 Patterson, M. K., Costello, D., Grimm, P., & Loeffler, M. (2007). Data center TCO; a comparison of high-density and low-density spaces. Thermal and Thermomechanical Phenomena in Electronic Systems, 2007. ITHERM '07., 10. https://doi.org/10.1109/ITHERM.2007.381507 Van Heddeghem, W., Lambert, S., Lannoo, B., Colle, D., Pickavet, M., &Demeester, P. (2014). Trends in worldwide ICT electricity consumption from 2007 to 2012. Computer Communications, 50, 64-76. https://doi.org/10.1016/j.comcom.2014.02.008 Tang, Q., Gupta, S. K. S., &Varsamopoulos, G. (2008). Energy-efficient thermal management of data centers via thermal storage. Parallel and Distributed Systems, IEEE Transactions on, 19(11), 1458-1472. https://doi.org/10.1109/TPDS.2007.70802 Mills, E. (2011). The cloud begins with coal: Big data, big networks, big infrastructure, and big power. Digital Power Group. http://www.tech-pundit.com/wp-content/uploads/2013/07/Cloud_Begins_With_Coal.pdf Kliazovich, D., Bouvry, P., & Khan, S. U. (2013). GreenCloud: A packet-level simulator of energy-aware cloud computing data centers. The Journal of Supercomputing, 62(3), 1263-1283. https://doi.org/10.1007/s11227-0100504-1 Beloglazov, A., &Buyya, R. (2010). Energy efficient allocation of virtual machines in cloud data centers. 10th IEEE/ACM International Conference on Cluster, Cloud and Grid Computing. https://doi.org/10.1109/CCGRID.2010.45 Mazzucco, M., &Dyachuk, D. (2011). Maximizing cloud providers revenues via energy aware allocation policies. 2011 IEEE International Conference on Cloud Computing (CLOUD). https://doi.org/10.1109/CLOUD.2011.42 Gao, Y., Guan, H., Qi, Z., Hou, Y., & Liu, L. (2013). A multi-objective ant colony system algorithm for virtual machine placement in cloud computing. Journal of Computer and System Sciences, 79(8), 1230-1242. https://doi.org/10.1016/j.jcss.2013.02.005 53 International Journal of Open Publication and Exploration (IJOPE), ISSN: 3006-2853 Volume 11, Issue 1, January-June, 2023, Available online at: https://ijope.com [26]. Wang, L., Khan, S. U., Chen, D., Kołodziej, J., Ranjan, R., Xu, C. Z., &Zomaya, A. Y. (2014). Energy-aware parallel task scheduling in a cluster. Future Generation Computer Systems, 29(7), 1661-1670. https://doi.org/10.1016/j.future.2012.05.021 [27]. Li, Z., O'Brien, L., Zhang, H., & Cai, R. (2012). On a catalogue of metrics for evaluating commercial cloud services. 13th International Conference on Grid Computing. https://doi.org/10.1109/Grid.2012.16 [28]. Geissdoerfer, M., Savaget, P., Bocken, N.M.P., &Hultink, E.J. (2017). The Circular Economy – A New Sustainability Paradigm. Journal of Cleaner Production, 143, 757-768. https://doi.org/10.1016/j.jclepro.2016.12.048 [29]. Olivetti, E.A., Ceder, G., Gaustad, G.G., & Fu, X. (2017). Lithium-Ion Battery Supply Chain Considerations: Analysis of Potential Bottlenecks in Critical Metals. Joule, 1(2), 229-243. https://doi.org/10.1016/j.joule.2017.08.019 [30]. Harper, G., Sommerville, R., Kendrick, E., Driscoll, L., Slater, P., Stolkin, R., Walton, A., Christensen, P., Heidrich, O., Lambert, S., Abbott, A., Ryder, K., Gaines, L., & Anderson, P. (2019). Recycling Lithium-Ion Batteries from Electric Vehicles. Nature, 575, 75–86. https://doi.org/10.1038/s41586-019-1682-5 [31]. Gaines, L. (2014). The Future of Automotive Lithium-Ion Battery Recycling: Charting a Sustainable Course. Sustainable Materials and Technologies, 1-2, 2-7. https://doi.org/10.1016/j.susmat.2014.10.001 [32]. Notter, D.A., Gauch, M., Widmer, R., Wäger, P., Stamp, A., Zah, R., & Althaus, H.-J. (2010). Contribution of Li-Ion Batteries to the Environmental Impact of Electric Vehicles. Environmental Science & Technology, 44(17), 65506556. https://doi.org/10.1021/es903729a 54