AUXILIARY POWER UNITHome > Aircraft Systems > APU | ||
Contents
|
Page Contents
|
All of the information, photographs & schematics from this website and much more is now available in a 374 page printed book or in electronic format. *** Updated 05 Aug 2023 *** |
The APU is a source of bleed air and AC electrics for the aircraft, this gives independence during turnarounds, electrical backup in the event of engine failure and provides air conditioning & pressurisation during an engine bleeds off take-off. It's electrical power source is the battery, many series -500 aircraft have an extra, dedicated APU battery to preserve main battery usage. There are many different APUs available for the 737. The Garrett GTCP (Gas Turbine Compressor [air] Power unit [electrics]) 85-129 was standard for the series 1/200 but when the -300 was introduced it was found that two to three times the energy was needed to start the larger CFM56 engines. Garrett produced the 85-129[E] which had a stretched compressor, ie the impellers were lengthened and the tip diameters increased. When the 737-400 was introduced, even more output was required and Garrett produced the 85-129[H]. This has an Electronic Temperature Control which limits hot section temperatures depending upon demand and ambient temperatures. By 1989 the 85-129[H] was the most common APU, although there are actually 14 different models of the 85-129 in service with 737s (see table below). Other APUs available for the Classic were the Garrett GTCP 36-280(B) and the Sundstrand APS 2000; NGs have the Allied Signal GTCP 131-9B. The main difference between them is that the Garrett is hydro-mechanical whereas Sundstrand and Allied Signal are FADEC controlled. I am told by engineers that whilst the Garrett is more robust, the Sundstrand and Allied Signal APUs are easier to work on. On the 3/4/500s, we pilots prefer the Sundstrand because it has no EGT limits and faster restart wait times. The easiest way to tell which is fitted is to look at the EGT gauge limits; the GTCP 85-129 has an 850C limit and also runs at 415Hz, the GTCP 36-280 has an 1100C limit if no EGT limits are marked you have a Sundstrand. Later aircraft have MAINT instead of LOW OIL QUANTITY and FAULT instead of HIGH OIL TEMP warning lights. The AlliedSignal APU has a 41,000ft start capability and incorporates a starter/generator, thus eliminating a DC starter and clutch. In practice this means that it can be started either by battery or AC transfer bus 1 (the classics are battery start only). It has an educter oil cooling system (see Bottom of page advert) and therefore has no need for a cooling fan. It is rated at 90KVA up to 31,000ft and 66KVA up to 41,000ft. The Garrett and Sundstrand APUs are only rated to 55KVA. The fuel source is normally from the No 1 main tank and it is recommended that at least one pump in the supplying tank be on during the start sequence (and whenever operating) to provide positive fuel pressure and preserve the service life of the APU fuel control unit. Boeing responded to this need by installing an extra DC operated APU fuel boost pump in the No 1 tank on newer series 500 aircraft which automatically operates during APU start and shuts off when it reaches governed speed. You can quickly tell if this is installed by looking for the APU BAT position on the metering panel and the APU BAT OVHT light on the aft overhead panel. It is recommended that the APU be operated for one full minute with no pneumatic load prior to shutdown. This cooling period is to extend the life of the turbine wheel of the APU.
Components
Sundstrand APS 2000 APU TimerSome aircraft have APU timers fitted on the aft overhead panel, since APU running time cannot be measured by aircraft logbook time. Fire ProtectionThere is only one APU fire bottle, despite the fact that the handle can be turned in either direction! It is filled with Freon (the extinguishant) and Nitrogen (the propellant) at about 800psi. When the fire handle is turned, the squib is fired which breaks the diaphragm on the bottle, the pressure of the nitrogen then forces the freon into the APU compartment which suffocates the fire. Note that after a squib has been fired, the yellow disc on the fuselage may not blow completely clear, see photos below.
GeneralThe APU will auto-shutdown for the following reasons:
The OVERSPEED light may illuminate for any of the following reasons:
There is no CSD in the APU because it is a constant speed engine. If the APU appears to have started but no APU GEN OFF BUS
light is observed then you may have a hung start. The current limit is 125A -air and 150A -ground, due to
better airflow cooling on the ground. The galley power will automatically be
load shed if the APU load reaches 165A. Because of these limits, the APU may
only power one bus in the air. However, if you should accidentally take-off with
the APU on the busses then it will continue to power both busses. If the APU EGT
reaches 620-650°C, the bleed
air valve will modulate toward closed. (This can lead to an aborted engine start
if the electrics do not load shed first.) LOW OIL QTY/MAINT – When illuminated, you may continue to
operate the APU for up to 30 hrs. Note: this light is only armed when APU switch
is ON. FAULT – Although the malfunction will cause the APU to
auto-shutdown, additional restarts may be attempted. Max recommended start altitude – 25,000ft Classics; No limit NG's. Each start attempt uses approx 7mins of battery life. Classic: Switching the battery off will shutdown the APU on the ground only. NG: Switching the battery off will shutdown the APU in the air or on the ground.
Limitations & Operating Techniques:APU life can be shortened by incorrect operating techniques. This can be helped by allowing the correct warm-up & cool-down times and bleed configuration for each type of APU. They all differ slightly due to engine core and design differences, but the manifestation of the failure is usually a turbine wheel rotor and/or blade separation. The following table is based on manufacturers recommendations.
*Initiates automatic cool down cycle. Warm up period: The minimum time to run the APU before a pneumatic load is applied. This allows the turbine wheel temperature to stabilise before a load is applied. Whilst 3 minutes is the recommended figure, 1 minute should be the absolute minimum. Note an electrical load may be used with no warm up period. Bleed Pack Operation: The number of packs to use on the ground. APU's which should run both packs have load compressors to supply bleed air. So two pack operation gives both cooler turbine wheel temperatures and a lower fuel burn. Main Engine Start (MES) to APU shutdown: The cool-down time to allow after main engine start. Note also that there should be a minimum amount of time between turning off the pack(s) and starting the first engine. Additionally, minimum delay should occur between starting the first & second engine. This prevents the turbine wheel temperature from decreasing and then significantly increasing when the second engine is started. APU shutdown: The cool-down time to allow after flight, after the packs have been switched off. Note, it is important to allow the APU to complete their shutdown sequence before the battery is switched off. Ref: Flt Ops tech Bulletin 99-1 Pack Operation and Fuel FlowSingle pack operation is not recommended with the Allied Signal 131-9 APU. The following 737-700 CDU BITE pages show the reason why: A single pack must work harder than two packs to cool the cabin to a given temperature. Hence the APU must supply higher bleed air pressures to assure proper environmental control system operation. This higher pressure requires a greater Inlet Guide Vane (IGV) open position than that required for 2–pack operation. Since there is less airflow required to operate 1–pack than is needed, a significant amount of unused bleed air is exhausted through the Surge Control Valve (SCV). This higher IGV open position and large quantity of unused air translates into higher APU fuel burn and higher EGTs during 1–pack operation. Also, the high airflow levels exhausting through the surge control valve increases the overall APU generated noise by 2dbA. With 2 packs supplying the cabin cooling requirements the pressure requirement is lower, resulting in lower turbine inlet temperatures, EGTs and far less unused air being discharged through the surge valve. APU Shutdown cool-down cycleThe FCOM (7.30.3) and AMM (49-11-00/200) tells us that the APU should be operated for a minute without bleed air before shutting down. This is all done automatically by selecting the APU master switch OFF. However, if the battery master switch is switched off during this minute, the cooling cycle will be aborted causing damage to the APU. Aborted cool-downs result in coked oil at the turbine seal and coked fuel on the fuel nozzle. The coked oil at the turbine seal will accelerate oil consumption. The coked fuel on the fuel nozzle can result in hot streaks through the APU that can cause localized damage to the combustor and the first stage turbine nozzle and accelerates wear through the entire hot section. Engineering can identify when this has happened from the FMC CDU as follows: APU BITE TEST IDENT/CONFIG - DATA MEMORY MODULE and look for ‘ABRTCLDN’ (aborted cool down). MAX APUThe MAX APU is still a Honeywell 131-9[B] but is updated to series 41 which has various minor improvements such as improved starting reliability. Externally, the tailcone has been extended 43 inches for streamlining; this has enabled the aft body vortex generators to be removed and gives an overall reduction in fuel burn of 1%. The eductor inlet has moved to the right side of the tailcone and the air inlet door has been redesigned with the removal of the NACA duct and vortex generator. The inlet door is hinged at the aft end and opens outward into the airstream, it has three positions: Closed, Ground position (45deg) and Flight position (17deg). Normal door transitions take 40 to 120 seconds between positions. You can despatch with the door locked in the flight position at a 1% fuel burn penalty. 737 MAX APU air inlet closed 737 MAX APU air inlet open The APU fire bottle contains HALON and Nitrogen. There is a customer option for an automatic APU fire extinguisher discharge whereby the APU fire extinguisher will discharge automatically 10 seconds after an APU fire warning is detected on the ground when main engines are not operating. The EGT gauge has been removed from the APU panel on the overhead panel and the blue MAINT light has been changed to an amber DOOR light. Illumination of the DOOR light simply means that the door did not reach the commanded position within 165 seconds. The APU can continue to be used, but some buffeting may be experienced and a fuel burn penalty of 2.4% should be applied. There are three new status messages to replace the MAINT light as follows:
High Efficiency Mode optionIn 2023 Honeywell released a High Efficiency Mode (HEM) upgrade for its 131-9B APU for the 737 NG/MAX. HEM is enabled by a new, highly efficient diffuser, controlled by software that autonomously regulates airflow to the APU compressor section. The HEM capability upgrade provides fuel savings and efficiency as well as CO2 emissions savings of 1% to 2% (estimated reduction of 0.5 to 0.6 gallons per APU hour) and increase time-on-wing by up to 1,500 APU flight hours, lowering fuel and maintenance costs. Honeywell quote 5 Reasons to upgrade to 131-9A HEM:
The upgrade is an easy, one-time modification enabled with software. Newer series 49 and above 131-9B APUs are already delivered with the new diffuser, which enables an on-wing upgrade to HEM. The FutureBack in 2003 Boeing conducted tests of a Solid Oxide Fuel Cell (SOFC) APU. The SOFC uses jet fuel as the reformer in the proton exchange membrane to give a 440kW APU that is 75% efficient compared to the conventional 40-45% efficient APUs. This could give a typical fuel saving of 1,360t for a 737 over a year. It was actually a hybrid gas turbine / SOFC due to the sudden surges in demand eg engine starts and gear retraction etc. The SOFC would use air from a compressor passed through a heat exchanger for its gas turbine section. The last detailed report I read on this subject, published by Whyatt & Chick in 2012, was assessing suitability for SOFC APU on the much more electric 787. It concluded that the SOFC would have to improve its power to weight ratio by at least a factor of 2 to break even on power produced against the fuel burn to carry its increased weight over a conventional APU. Another potential drawback is that a SOFC has a 40min start-up time, so it would have to remain on for the whole day. Although much quieter than gas turbines, this could still be a problem at airports which require the APU to be shutdown during the turnaround for environmental reasons. The technology for the SOFC APU to replace the current APU is not likely to be available until at least 2020.
The following information applies mainly to the operation of the APU's installed on the 737-300 to MAX. For notes about -200 series APU operation, see notes by Jordaan or Ferreira. Much of this information is common across all series of 737. |