Papers by Frederik Winther

A two-bed hospital ward with one standing healthcare assistant and a ceiling-mounted low-impulse ... more A two-bed hospital ward with one standing healthcare assistant and a ceiling-mounted low-impulse semicircular inlet diffuser is simulated in a full-scale room. Tracer gas is used for simulating gaseous contaminants, and the concentration is measured at different air change rates and different postures of the patients. A textile partition between the beds, which is typical in a hospital ward, is used for protection of the patients in some of the experiments. Three different layouts of return openings are tested. One layout with one opening at the ceiling, another with four openings at the wall opposite to the inlet diffuser, and one with a high location of these four openings. The downward recirculating flow is on average parallel with the partition, and the partition does not decrease cross infection. A high location of the four return openings decreases the risk of cross infection.
Ashrae Transactions, 2008
Der gøres opmaerksom på, at denne publikation er omfattet af ophavsretsloven. Layout og trykning ... more Der gøres opmaerksom på, at denne publikation er omfattet af ophavsretsloven. Layout og trykning af denne publikation er gjort mulig med ALECTIA Prisen 2010, der blev tildelt Strategisk Forskningscenter for Energineutralt Byggeri af ALECTIA Fonden. C I 2035 forventes det, at bygningsmassens energibehov kan daekkes ved vedvarende energi fra nettet. Desuden kan der suppleres med egenproduktion (el og varme).
치환환기 등의 예를 제하면 통상 공조시스템은 실내의 공기를 충분히 확산시키는 것으로 생각되고 있다. 이 확산의 상황과 수동흡연, 교차감염이나 그 외의 인체간의 상호 작용에의 ... more 치환환기 등의 예를 제하면 통상 공조시스템은 실내의 공기를 충분히 확산시키는 것으로 생각되고 있다. 이 확산의 상황과 수동흡연, 교차감염이나 그 외의 인체간의 상호 작용에의 영향에 관해서는 미소 스케일로 많은 연구가 행해지고 있다. 본 보고에서는 실내에서 인체산호의 미소환경의 흐름을 언급한다. 인체 주위의 흐름이 각종방법으로 인체에 영향을 준다는 것은 널리 알려져 있다. 사람과 사람이 일정거리를 가지고 위치하는 경우, 통상의 공조라면 오염물질을 충분히 확산시키고, 사람으로부터 오염물질 발생이 다른 사람에 고농도인 상태로 수송되는 것을 막는다. 그러나, 만약 사람과 사람이 가까이에 위치하는 경우, 사람으로부터 오염물질 발생이 고농도인 상태로 직접 다른 사람에게 도달할 가능성이 있다. 본 보고에서 소개하는 실험은 열 마네킹으로 행하고 흡기의 흐름을 트레이스 가스로 재현하였다. 실험에서는 어떤 마네킹에서 다른 마네킹으로 트레이스 가스의 도달에는 2개의 패턴이 있는 것을 나타낸다. 하나는 실내의 백그라운드 농도의 영향에 의해 수송되는 것이고, 다른 하나는 호흡에 의해 직접적인 수송이 된다. 이러한 미소환경에 대한 영향은, 인체의 거리가 1.2 m 이하로 되는 경우에 특히 중요하다. 본 보고에서는 각종 공조시스템을 이용한 경우에 이 미소환경의 영향을 보고한다.
Page 7 Emneord Facader, dynamiske facader, intelligente facader, Klassificering, Bygningsreglemen... more Page 7 Emneord Facader, dynamiske facader, intelligente facader, Klassificering, Bygningsreglement, BR18, BK2020, Be18 ISBN 978-87-563-1890-7 Illustrationer Forfatterne, hvor ingen andre er naevnt Fotos Forfatterne, hvor ingen andre er naevnt Omslagsfoto Forfatterne

Energy and Buildings, 2013
The study aims to develop a simplified calculation method to simulate the performance of double g... more The study aims to develop a simplified calculation method to simulate the performance of double glazing fac ¸ ade with night insulation. This paper describes the method to calculate the thermal properties (Uvalue) and comfort performance (internal surface temperature of glazing) of the double glazing facade with the night insulation. The calculation result of the internal glazing surface temperature has been validated with experimental data collected in a full-scale fac ¸ ade element test facility at Aalborg University (DK). With the help of the simplified method, dynamic U-value of the facade with night insulation is calculated and compared with that of the facade without the night insulation. Based on standards EN 410 and EN 673, the method takes the thermal mass of glazing and the infiltration between the insulation layer and glazing into account. Furthermore it is capable of implementing whole year calculation at different time steps. Acceptable accuracy and simplicity inputs are also the advantages of the method, which make it a suitable tool to evaluate the performance of night insulation during the design stage of buildings. The result calculated by the method proves that the facade with the night insulation performs much better than that without the night insulation.
Building Simulation, 2016
Journal of Building Performance Simulation, 2015
Building Simulation, 2015
This project aims at testing technologies for control of heat transfer, irradiation, mass transpo... more This project aims at testing technologies for control of heat transfer, irradiation, mass transport and energy storage in order to investigate the potential of a intelligent dynamic glazed facade. Furthermore a development of algorithms for control of the technologies included in the facade, for use in the design phase, is done. The methods used are initially based on thermal building calculations. This analysis shows that a dynamic adaptive facade is the only way in which future office buildings can fulfil the energy regulations. By designing the facade according to the usage and the microclimate, the energy usage of the building can be lowered significantly and fulfil energy regulations for 2020.
A two-bed hospital ward with one standing healthcare assistant and a ceiling-mounted low-impulse ... more A two-bed hospital ward with one standing healthcare assistant and a ceiling-mounted low-impulse semicircular inlet diffuser is simulated in a full-scale room. Tracer gas is used for simulating gaseous contaminants, and the concentration is measured at different air change rates and different postures of the patients. A textile partition between the beds, which is typical in a hospital ward, is
Uploads
Papers by Frederik Winther