## Supported functionality

{% note %}
This NUT integration uses the NUT protocol to retrieve "variables"
from the NUT server. Only sensors and diagnostic sensors available for
your device are added to Home Assistant.
{% endnote %}

{% important %}
The username and password configured for the device must be granted
`instcmds` permissions on the NUT server to use buttons and
Expand All @@ -74,6 +80,178 @@ documentation](https://networkupstools.org/documentation.html) for
configuration information.
{% endimportant %}

### Sensors

Sensors provide information about a NUT device.

The following sensors may be available:

- **Alarms**: UPS alarms
- **Battery charge (%)**: Battery charge
- **Charging status**: Status of the battery charger, with the available states: `charging`, `discharging`, `floating`, `resting`, `unknown`, `disabled`, and `off`
- **Input current (A)**: Input current
- **Input load (%)**: Load on (ePDU) input
- **Input voltage (V)**: Input voltage
- **Load (%)**: Load on UPS
- **Outlet voltage (V)**: Total output voltage
- **Output phases**: Output phases
- **Output voltage (V)**: Output voltage
- **Status**: Human-readable version of "Status data" (see below)
- **Status data**: UPS status

The **Status data* sensor is translated into a human-readable virtual
sensor named **Status**.

Some power devices provide monitoring information about individual
outlets. The following sensors may be available for each such outlet:

- **Outlet NAME current (A)**: Current of named outlet
- **Outlet NAME description**: Description of named outlet
- **Outlet NAME power (VA)**: Apparent power of named outlet
- **Outlet NAME real power (W)**: Real power of named outlet

Additional information about the values reported for these sensors can
be found in the Network UPS Tools repository documentation on
[variable names](https://github.com/networkupstools/nut/blob/master/docs/nut-names.txt).

### Diagnostic sensors

Diagnostic sensors provide additional information about a NUT device.

{% important %}
Most of this integration's diagnostic sensors are disabled by default
to reduce storage overhead for Home Assistant. The diagnostic sensors
marked with an asterisk \* are enabled by default. To use a disabled
sensor, you need to enable them first. See the [enabling or disabling
entities](/common-tasks/general/#enabling-or-disabling-entities)
documentation for information on how to do this.
{% endimportant %}

{% note %}
Certain diagnostic sensor values are described as "opaque by mfg" in
the table below and NUT's documentation. This means the value returned
for the sensor may vary by manufacturer.
{% endnote %}

The following diagnostic sensors may be available:

- **Ambient humidity (%)**\*: *Ambient relative humidity
- **Ambient humidity status**\*: Ambient humidity status relative to the thresholds, with the available states: `good`, `warning-low`, `critical-low`, `warning-high`, and `critical-high`
- **Ambient temperature (°C)**\*: Ambient temperature
- **Ambient temperature status**\*: Ambient temperature status relative to the thresholds, with the available states: `good`, `warning-low`, `critical-low`, `warning-high`, and `critical-high`
- **Apparent power (VA)**: Current value of apparent power
- **Battery alarm threshold**: Battery alarm threshold
- **Battery capacity (Ah)**: Battery capacity
- **Battery chemistry**: Battery chemistry (opaque by mfg)
- **Battery current (A)**: Battery current
- **Battery date**: Battery installation or last change date (opaque by mfg)
- **Battery manuf date**: Battery manufacturing date (opaque by mfg)
- **Battery runtime (secs)**: Battery runtime
- **Battery temperature (°C)**: Battery temperature
- **Battery voltage (V)**: Battery voltage
- **Beeper status**: UPS beeper status, with the available states: `enabled`, `disabled`, and `muted`
- **Efficiency (%)**: Efficiency of the UPS (ratio of output to input current)
- **External contacts**: UPS external contact sensors (opaque by mfg)
- **High battery voltage (V)**: Maximum battery voltage (100% charge)
- **High voltage transfer (V)**: High voltage transfer point
- **Input L1 current (A)**: Input L1 current
- **Input L1 line frequency (Hz)**: Input L1 line frequency
- **Input L1 real power (W)**: Input L1 current sum value of all (ePDU) phases real power
- **Input L1-N voltage (V)**: Input L1-N voltage
- **Input L2 current (A)**: Input L2 current
- **Input L2 line frequency (Hz)**: Input L2 line frequency
- **Input L2 real power (W)**: Input L2 current sum value of all (ePDU) phases real power
- **Input L2-N voltage (V)**: Input L2-N voltage
- **Input L3 current (A)**: Input L3 current
- **Input L3 line frequency (Hz)**: Input L3 line frequency
- **Input L3-N voltage (V)**: Input L3-N voltage
- **Input L3 real power (W)**: Input L3 current sum value of all (ePDU) phases real power
- **Input bypass L1 current (A)**: Input bypass L1 current
- **Input bypass L1 real power (W)**: Input bypass L1 value of real power
- **Input bypass L1-N voltage (V)**: Input bypass L1-N voltage
- **Input bypass L2 current (A)**: Input bypass L2 current
- **Input bypass L2 real power (W)**: Input bypass L2 value of real power
- **Input bypass L2-N voltage (V)**: Input bypass L2-N voltage
- **Input bypass L3 current (A)**: Input bypass L3 current
- **Input bypass L3 real power (W)**: Input bypass L3 value of real power
- **Input bypass L3-N voltage (V)**: Input bypass L3-N voltage
- **Input bypass current (A)**: Input bypass current
- **Input bypass frequency (Hz)**: Input bypass line frequency
- **Input bypass phases**: Input bypass line phases
- **Input bypass real power (W)**: Input bypass value of real power
- **Input bypass voltage (V)**: Input bypass voltage
- **Input current status**: Current status relative to the thresholds, with the available states: `good`, `warning-low`, `critical-low`, `warning-high`, and `critical-high`
- **Input frequency (Hz)**: Input line frequency
- **Input frequency status**: Frequency status, with the available states: `good` and `out-of-range`
- **Input nominal frequency (Hz)**: Nominal input line frequency
- **Input phases**: Input line phases
- **Input power (VA)**: Current sum value of all (ePDU) phases apparent power
- **Input power sensitivity**: Input power sensitivity
- **Input real power (W)**: Current sum value of all (ePDU) phases real power
- **Input voltage status**: Status relative to the thresholds
- **Language**: Language to use on front panel (opaque by mfg)
- **Load reboot timer (secs)**: Time before the load will be rebooted
- **Load restart delay (secs)**: Interval to wait before restarting the load
- **Load shutdown timer (secs)**: Time before the load will be shutdown
- **Load start timer (secs)**: Time before the load will be started
- **Low battery runtime (secs)**: Remaining battery runtime when UPS switches to low battery (LB)
- **Low battery setpoint (%)**: Remaining battery level when UPS switches to low battery (LB)
- **Low battery voltage (V)**: Minimum battery voltage that triggers FSD status
- **Low voltage transfer (V)**: Low voltage transfer point
- **Minimum battery runtime to start (secs)**: Minimum battery runtime for UPS restart after power-off
- **Minimum battery to start (%)**: Minimum battery level for UPS restart after power-off
- **Nominal battery voltage (V)**: Nominal battery voltage
- **Nominal input voltage (V)**: Nominal input voltage
- **Nominal output current (A)**: Nominal output current
- **Nominal output frequency (Hz)**: Nominal output frequency
- **Nominal output power (VA)**: Nominal output apparent power
- **Nominal output real power (W)**: Nominal output real power
- **Nominal output voltage (V)**: Nominal output voltage
- **Nominal power (VA)**: Nominal value of apparent power
- **Nominal real power (W)**: Nominal value of real power
- **Number of bad batteries**: Number of bad battery packs
- **Number of batteries**: Number of internal battery packs
- **Output L1 current (A)**: Output L1 current
- **Output L1 power percent (%)**: Output L1 percentage of apparent power relative to maximum load
- **Output L1 real power (W)**: Output L1 real power
- **Output L1-N voltage (V)**: Output L1-N voltage
- **Output L2 current (A)**: Output L2 current
- **Output L2 power percent (%)**: Output L2 percentage of apparent power relative to maximum load
- **Output L2 real power (W)**: Output L2 real power
- **Output L2-N voltage (V)**: Output L2-N voltage
- **Output L3 current (A)**: Output L3 current
- **Output L3 power percent (%)**: Output L3 percentage of apparent power relative to maximum load
- **Output L3 real power (W)**: Output L3 real power
- **Output L3-N voltage (V)**: Output L3-N voltage
- **Output apparent power (VA)**: Output apparent power
- **Output current (A)**: Output current
- **Output frequency (Hz)**: Output frequency
- **Output phases**: Output phases
- **Output real power (W)**: Output real power
- **Overload setting (%)**: Load when UPS switches to overload condition
- **Real power (W)**: Current value of real power
- **Reboot on battery**: UPS coldstarts from battery
- **Self test date**: Date of last self test (opaque by mfg)
- **Self test interval (secs)**: Interval between self tests
- **Self test result**: Results of last self test (opaque by mfg)
- **Shutdown ability**: Enable or disable UPS shutdown ability
- **Start on ac**: UPS starts when power is applied or re-applied
- **Start on battery**: Allow to start UPS from battery
- **System identifier**: UPS system identifier (opaque by mfg)
- **Total battery current (A)**: Total battery current
- **UPS reboot delay (secs)**: Interval to wait before rebooting the UPS
- **UPS shutdown delay (secs)**: Interval to wait after shutdown with delay command
- **UPS temperature (°C)**: UPS temperature
- **UPS type**: UPS type (opaque by mfg)
- **Voltage transfer reason**: Reason for last transfer to battery (opaque by mfg)
- **Warning battery setpoint (%)**: Battery level when UPS switches to "Warning" state
- **Watchdog status**: UPS watchdog status

The following diagnostic sensors may be available for each
individually monitored outlet:

- **Outlet NAME current status**: Current status relative to the thresholds for the named outlet

### Buttons

This NUT integration will add buttons for NUT server commands
Expand Down Expand Up @@ -141,12 +319,6 @@ output.voltage.nominal: 120
Use the values from the left hand column. Support is included for most
values with `ups`, `battery`, `input` and `output` prefixes.

## UPS Status - human-readable version

An additional virtual sensor type `ups.status.display` is available
translating the UPS status value retrieved from `ups.status` into a
human-readable version.

## Device Actions

A device action is available for each parameterless NUT [command](https://networkupstools.org/docs/user-manual.chunked/apcs03.html) supported by the device. To find the list of supported commands for