fix impulse size for discrete-time impulse response #447
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
The input impulse used to drive the impulse response of a discrete-time system should be unit area rather than unit height. With this change, the discrete-time system's impulse response matches the cont-time systems's, if the discrete time system was sampled with 'impulse-equivalent' approximation according to:
sysd = sys.sample(0.1, 'impulse')
A new unit test checks this.
(this is consistent with MATLAB behavior)