Skip to content

Conversation

sawyerbfuller
Copy link
Contributor

The damp command was assuming a cont-time system when printing out pole locations (but the return value was correct). Fixed, along with making a few docstring improvements.

@sawyerbfuller
Copy link
Contributor Author

Example:

sysd = ct.zpk([], [-1.1, 1+1j, 1-1j], 1, True)
ct.damp(sysd)

Old (pole at -1.1 has the wrong frequency, table is hard to read):

_____Eigenvalue______ Damping___ Frequency_
         1        +1j    -0.4037     0.8585
         1        -1j    -0.4037     0.8585
      -1.1                     1        1.1

New:

    Eigenvalue (pole)       Damping     Frequency
         1        +1j       -0.4037        0.8585
         1        -1j       -0.4037        0.8585
                 -1.1             1         3.143

@murrayrm
Copy link
Member

LGTM.

@murrayrm murrayrm merged commit 1b84d80 into python-control:main May 28, 2023
@murrayrm murrayrm added this to the 0.9.4 milestone Jun 7, 2023
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment