Original file line number Diff line number Diff line change
Expand Up @@ -54,6 +54,13 @@ void setup() {

static int32_t readVref()
{
#ifdef STM32U0xx
/* On some devices Internal voltage reference calibration value not programmed
during production and return 0xFFFF. See errata sheet. */
if ((uint32_t)(*VREFINT_CAL_ADDR) == 0xFFFF) {
return 3300U;
}
#endif
#ifdef __LL_ADC_CALC_VREFANALOG_VOLTAGE
#ifdef STM32U5xx
return (__LL_ADC_CALC_VREFANALOG_VOLTAGE(ADC1, analogRead(AVREF), LL_ADC_RESOLUTION));
Expand Down