Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Moisture Properties of Plaster and Stucco for
Strawbale Buildings
John Straube
1 Introduction
Straw, as a fiber, has been used as part of building materials for several
thousand years. With the invention of the mechanical baler in the early 1900’s
it became possible for compressed straw to be used as the primary building
block of exterior building walls. Although strawbale (SB) houses were popular
for a short while in a local area of Nebraska, they lost favor for nearly half a
century. There has recently been a rebirth in SB house construction and
interest. In many cases the interest stems from the highly insulating, simple,
and sustainable nature of SB walls.
Although there is a large and growing body of empirical evidence that strawbale
buildings can be used very successfully, the scientific justification and
explanation is lacking, and hence accepted engineering approaches to design,
testing, and inspection have not been well developed.
To support the growing volume of rice straw agricultural waste the State of
California supported a research program to improve the level of scientific
knowledge of strawbale wall behavior and performance.
This report is a draft summary of the results of the moisture property testing of
a range of plaster types that might be installed over strawbale walls. It reviews
the literature for previous data, describes the test protocols, and summarizes
the results.
1.1
Plaster -- Strawbale Skins
The most common and time-proven strawbale wall assembly consists of
strawbales with 1 to 3” (25 to 75 mm) thick mineral-based stucco skins applied
to both faces. In modern times, the stucco skin is often made of steel mesh
reinforced cement stucco skins applied directly to the strawbales. For reasons
of performance, cost, sustainability, health, and ease of construction the use of
Balanced Solutions.com
1
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
non-cement mineral binders such as lime, earth and gypsum has grown.
Regardless of what it is made, the plaster skins provide a finish, a weather
barrier, an air barrier, fire protection, rodent and insect control. Since they are
usually the stiffest part of a wall assembly, the skins also often act as structural
elements, whether intentionally or not.
Straw, like wood, degrades when exposed to a sufficient amount of moisture
for a sufficient amount of time at above-freezing temperatures. Therefore, one
of the major performance-related concerns of strawbale enclosure walls is
moisture control. Moisture control is a complex subject that requires an
understanding of climate, micro-climate, building details, enclosure assembly,
and interior conditions. The material properties of straw and plaster are critical
to the understanding of the enclosure assembly part of moisture control.
Building enclosure strawbale walls with appropriate moisture tolerance is best
achieved by selecting materials and assemblies that ensure a balance of wetting
and drying potentials, with an appropriate amount of safe storage capacity,
given the conditions the walls are expected to separate. Understanding and
predicting wetting and drying is therefore of fundamental importance to
predicting and improving performance, and particularly durability, of strawbale
enclosure walls.
1.2
Project Scope and Objectives
To allow for the prediction of heat and moisture performance, material
properties are needed. In strawbales walls, the strawbale core and plaster skins
are usually the only materials whose properties are of interest. However, there
is a wide variety of plaster types, additives, and coatings.
The most important properties to measure are the vapor and liquid diffusivity
and moisture storage function of the skins, and the thermal resistance, vapor
diffusivity, and moisture storage function of the straw.
Measured vapor permeance values of stucco and some analysis of the level of
vapor permeance required for good performance are needed to assess if
sufficient vapor resistance is provided by interior plaster finishes to resist
diffusive vapour flow into walls in cold weather (and to meet the intent of
some building codes). Drying of walls is predominately a vapour diffusion
driven phenomenon. To predict the drying rate of water stored in straw bale
BalancedSolutions.com
2
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
walls, the vapor permeance of both the interior and exterior skins must be
known.
Air leakage and rain penetration are usually the two largest sources of moisture
in enclosure walls. Strawbales are very vapor and water permeable and hence
rely on the skins to control the entry of these sources of moisture. While
almost all wet-applied monolithic plaster finishes are sufficiently air
impermeable to control air flow, their liquid water absorption are highly
variable and poorly known. The ability of an exterior plaster to absorb and
store rainwater is critical since this water can then be transported inward to the
strawbales by vapor diffusion and capillarity.
To aid in the control of rain penetration and absorption, water repellents and
sealers have been proposed as simple and relatively inexpensive solutions.
Manufacturer's and designers often do not understand the effect of such
products on liquid and vapor transport of moisture across the outer skin
because of a lack of material property information. Such information would be
very useful to guide strawbale builders in their choice of a climate-appropriate
finish.
The thermal resistance of the strawbales are important for the insulating
function required of modern enclosure wall systems. The thermal resistance
also affects the temperatures experienced by the skins when exposed to varying
temperatures over the day, and this greatly influences the flow of water vapor.
Thermal resistance has been measured by others, is similar to other cellulosic
materials of similar density, and the literature is being reviewed as part of
another EBNet project. Hence, the work reported here did not involve thermal
resistance testing.
Given the material properties described above interior and exterior
environmental conditions computer models can predict, with reasonable
accuracy, the temperature and moisture conditions within a wall system.
1.3
Technical Background
The material properties described in this report are fundamental building
science properties that may not be familiar to all readers. Hence, the
terminology is reviewed in this section.
BalancedSolutions.com
3
Moisture Properties of Plaster and Stucco for Strawbale Buildings
1.3.1
EBNet
Thermal Conductivity
Thermal conductivity (symbol k or λ) is a fundamental material property that
describes the rate of heat flow across a unit area, through a unit thickness for a
temperature gradient of one degree. The symbol λ is often used in Europe
instead of k.
Units: SI
W / m·K
Imperial
Btu·in / (hr·ft2·°F)
Conversion 0.144 Btu· in / (hr·ft2·°F) = W / m·K
Thermal conductivity often varies with the mean temperature and the
magnitude of the temperature differential. Standards normally specify these
values so that different materials can be compared.
Units: SI
W / m2·K
Imperial
Btu / (hr·ft2·°F)
Conversion 5.678 Btu / (hr· ft2·°F) = W / m2·K or
Btu / (hr·ft2·°F) = 0.176 W / m2·K
Thermal resistance is the reciprocal of conductance.
Resistance = 1/C = thickness / conductivity = l/k.
Units: SI
(m2·K ) / W (RSI)
Imperial
hr·ft2·°F / Btu
Conversion R = 5.678·RSI or RSI = 0.176 R
Hence, R-value is valid for a specific wall thickness, temperature difference,
and temperature across the specimen. It is not uncommon for R-values to be
reported as R-values per inch, so that users can simply multiply the given value
by the thickness of the material to assess the total R-value.
It should be emphasized that the heat flow decreases with the inverse of Rvalue, that is:
Heat flow = 1 / R-value * Temperature difference
BalancedSolutions.com
4
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Hence, the reduction in heat flow as the a walls R-value increases from 20 to 25
(a reduction of 0.01 in heat flow) is small compared to the increase in R-value
from R10 to R15 (a reduction of 0.033), the R-value increase achieved by
moving from a typical 2x4 wall to a 2x6 wall in many modern homes. Debates
over the difference in R-value of 25 or 29 are essentially academic, since the
heat flow is so small that little benefit would be gained by the increase.
1.3.2
Vapor Permeability
Vapour permeability is a material property, expressed independently of material
thickness, in units of ng/Pa s m, and given the symbol, µ. Vapour permeance
is a measure of the ease of vapour flow through a material layer, in units of
perms (equal to 1 ng/Pa s m2 or 1 grain/(hr·in Hg· ft2)) and given the symbol
M. Permeability and permeance are analogous to thermal conductivity and
thermal conductance respectively. Imperial US perms can be converted to
metric perms by multiplying by 57.1.
Many codes define a vapor barrier as any material or system that has a
permeance of less than 1 US perm. This is an arbitrary value based on a limited
and questionable study conducted in the 1940’s. Vapor diffusion flow through
a wall may need to be controlled with vapor resistant layer in some special
cases, but plastered strawbale alls usually don’t need them, and often appear to
perform much better without them.
1.3.3
Liquid Uptake
The water absorption coefficient is a measure of a materials ability to transport
capillary water. It is determined experimentally by measuring the rate of water
absorption when a sample is placed in contact with liquid water. The water
absorption coefficient so determined can then be used to estimate the liquid
diffusivity, the fundamental measure of liquid water movement within porous
bodies.
There are no material property standard requirements for it in North America
although German stucco standards provide upper limits if a stucco is to be
called “water repellent”.
In general, water absorption is measured in units of kg/m2 s0.5 and given the
symbol A.
BalancedSolutions.com
5
Moisture Properties of Plaster and Stucco for Strawbale Buildings
Units: SI
Imperial
EBNet
kg/m2 s0.5 (or kg/m2 h0.5 )
ounces/ft2 s0.5
Conversion 0.334 ounces/ft2 s0.5 = 1 kg/m2 s0.5
1.3.4
Moisture Storage
Surfaces in contact with water vapour molecules have the tendency to capture
and hold water molecules because of the polar nature of the water molecule;
this process is called adsorption. Most building materials are porous and have
very large internal surface areas. For example, brick typically has an internal
surface area of from 1 to 10 m2 /g, cement paste from 10 to 100 m2/g, and
wood, straw, or cellulose can have even larger surface areas. Therefore, as water
vapour molecules adsorb to the internal surfaces of these materials, the
materials' water content increases significantly, and the materials are then
described as hygroscopic . Materials such as plastic and steel do not have internal
pores and therefore are not hygroscopic -- they do not pick up moisture from
water vapour in the air.
As the relative humidity increases, the moisture content of porous materials
increases because more of the vapor in the air adheres to the materials’ pore
walls. When the RH exceeds about 80 to 90%, liquid water begins to form in
the smallest pores, and eventually in the larger pores.
The relationship of air relative humidity to moisture content is called the
sorption isotherm and is unique for each material (Figure 1.1). It may take weeks
or months for a thick solid material to reach equilibrium with its relative
humidity environment.
When a material has adsorbed all the vapor it can from the air (e.g., the
moisture that a material will adsorb when left in a 100%RH room for long
enough), further moisture will be stored in the pores and cracks within the
material by capillary suction, or by absorption. Only when all pores are filled
with water is a material capillary saturated. For example, wood (and likely
straw) will adsorb vapour from the air up to approximately 25% moisture
content at 98% relative humidity, but fully capillary saturated wood may hold
two to four times this amount of water. Once a material is capillary saturated it
will generally not be able to store any more moisture. Hence, when this
BalancedSolutions.com
6
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
moisture content is exceeded, a material is called over-saturated, and drainage,
if possible, will begin to remove the excess moisture.
20
Spruce
Plywood
Fibreboard
Red Brick
15
Mortar
Concrete
MC (M%)
Stucco
10
5
0
0
20
40
60
80
100
RH (%)
Figure 1.1: Sorption Isotherms for Several Common Building Materials
BalancedSolutions.com
7
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
2 Literature Review
As discussed above, most strawbale walls are made of plaster skins and a core
of strawbales. The properties of these individual materials as found from a
literature review will be briefly reviewed below.
2.1
Strawbales
The strawbale core acts primarily as thermal insulation while transferring
structural loads between the skins. Strawbales come in two main sizes, twostring and three-string, and a wide range of density. The density, which
typically varies from below 7 pcf to over 12 pcf (110 to 190 kg/m3 ) is the most
important variable to assess – it strongly affects R-value, stiffness, strength, and
air permeability.
2.1.1
Strawbale Thermal Conductivity
The thermal resistance of strawbales is dependent on straw type and density,
straw orientation, and thickness. Values of RSI3 (R17) to over RSI6 (R35)
have been reported, although for the common 450 mm (18”) thick strawbale of
110 to 190 kg/m3 (7 to 12 pcf) density, a value of at least RSI4 (R23) can be
expected.
Recent Danish [Andersen, 2000] research on full-scale wall samples found
thermal conductivity values that ranged from R2.4 to almost R2.8 per inch.
The bales were of an unknown straw species (not rice) and were of relatively
low density. Great care was taken to prevent air movement within the walls.
The group also studied highly compacted bales (37.4 pcf!) and found that
despite the high density, a R-value of about 1.3 per inch was still achieved.
Heat Flow Relative to
Straw Direction
Perpendicular
Perpendicular
Parallel
Parallel
Compacted
Density
(pcf)
4.8
5.9
4.8
5.7
37.4
R-value/inch
2.77
2.58
2.53
2.40
1.31
R-value / 18
inch
50
46
46
43
Table 2.1: Thermal Resistance measured for Danish Strawbale
BalancedSolutions.com
8
Moisture Properties of Plaster and Stucco for Strawbale Buildings
2.1.2
EBNet
Vapor and Liquid Permeability
The vapor permeance of strawbales have not been measured (as far as the
author is aware) but good estimates can be made. Based on published data for
the vapor permeance of highly porous natural materials such as cellulose
insulation (density= 25-50 kg/m3 / 1.6 to 3.2 pcf, µ=110-130 ), wood
fiberboard (density = 340 kg/m3 /21 pcf, µ=20-60), wood wool cement board
(density = 400 kg/m3/ 25 pcf µ=30-40), and light straw clay (density = 450
kg/m3 /28 pcf, µ=80) the vapour permeability is expected to be quite high, in
the order of µ=50 to 100 ng/Pa•s•m. This means that a 1 meter thick layer of
strawbale is expected to have a vapor permeance of 50 to 100 ng/Pa •s•m2, and
that a 450 mm thick strawbale should have a permeance of approximately 110
to 220 ng/ Pa•s•m2 (2 to 4 US perms).
The capillary transport properties of strawbale have also not been measured.
While the walls of the stalks will wick liquid water (because of the nature of the
small cellulosic walls), the bale itself is composed of mostly large pores which
will not wick water. Therefore, the water uptake of a strawbale will be slow,
and should quickly reach equilibrium with drying. In general, liquid transfer of
the straw has no practical importance since liquid water should not be allowed
to contact strawbales.
2.1.3
Moisture Storage
The moisture storage (sorption isotherm) of grasses and straws is of some
interest to agricultural engineers. It has been studied by many. Plots of some
of the data from Lamond and Graham [1993] are presented in Figure 2.1.
It can be seen that the sorption isothem is little affected by temperature (hence
the term isotherm) and that the curve is similar to that of wood. That the
response of straw, grass, and wood are similar is expected because of their
similar cellulose and lignin microstructure.
BalancedSolutions.com
9
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
40%
T=20 C
Moisture Content (M%)
T = 50 C
30%
T= -10 C
Spruce wood
Minke - rye grass
20%
10%
0%
0%
10%
20%
30%
40%
50%
60%
Relative Humidity (%)
70%
80%
90%
100%
Figure 2.1: Sorption Isotherms for Grasses [Lamond & Graham 1993]
2.2
Plaster / Stucco Skins
Stucco or exterior plaster, defined as a hardened mix of fine aggregate and
inorganic binders, is a highly desirable finish for walls and ceilings. Stucco that
uses sand aggregate and cementitous binders is and has been widely used
throughout the world for many years. In modern times, the stucco skin is often
made of steel mesh reinforced cement stucco skins applied directly to the
strawbales.
The stucco used in strawbale walls can range from high-strength gunite or
shotcrete to cement-lime mixtures to earth-based plasters with and without
lime or cement stabilizers. Common practice describes stucco mixes as a
volumetric ratio in the form C:L:S, where C is the cement component, L is the
lime component, and S is the sand component. In many strawbale buildings
typical stucco mixes are 1:3 cement stucco or 1:1:6 cement-lime stucco. Table
2.1 lists some of the common mixes and letter definitions from the Portland
Cement Association's Portland Cement Stucco Manual. The use of masonry
BalancedSolutions.com
10
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
cement is intended to replace the plasticizer function of lime. Pure lime
plasters are typically made with a ratio of about 1:3.
Type
(mortar
or stucco)
C/S
CM/N
L
M
O
K
Portland
Cement
1
1
1
Hydrated
Lime
1
1
Masonry
Cement
/2
1
1
/2 - 1 /4
1
1
2
1
Sand
First Coat
Sand
Second
Coat
Minimum
compressive
strength
(MPa)
5–8
5–8
5–8
5–8
5–8
5–8
6 - 10
6 – 10
6 – 10
6 – 10
6 – 10
6 - 10
12
5
5
?
2.4
0.5
Table 2.2: Recommended Stucco/Mortar Mixes, by volume of cement
Straube [2000] conducted a series of vapor permeance and water uptake tests
on a range of plaster finishes that had been applied to strawbales. The samples
were all lime or cement bonded, and investigated the influence of various
coatings on the moisture properties. Since this study is very similar and relevant
to the current study, it is reviewed in some depth here.
The samples tested included
A.
1:3 Cement: Sand
B.
1:1:6 Cement: Lime: Sand
C.
1:2:9 Cement: Lime: Sand
D.
1:3 Type S slaked Lime: Sand
A wide range of coatings and additives were tested on these basic stucco
samples. The samples and results are summarized in Table 2.3.
BalancedSolutions.com
11
Moisture Properties of Plaster and Stucco for Strawbale Buildings
Sample
Cement :Sand
1:3 datum
1:3 elastomeric coating
1:3 siloxane
Cement:Lime:Sand
1:1:6 datum
1:1:6 linseed
1:1:6 elastomeric
1:1:6 siloxane
1:1:6 calcium stearate
1:1:6 calcium stearate
1:1:6 calcium stearate
1:1:6 latex paint
1:1:6 oil paint
Cement:Lime:Sand
1:2:9 datum
1:2:9 linseed
Lime:Sand
1:3 Datum
1:3 Datum
1:3 Quicklime
EBNet
t
[mm]
Permeance
[ng/Pa s m2]
Permeability
[ng/Pa s m]
US Perms
43.5
39.5
41.0
39
40
40
1.7
-1.7
0.68
0.70
0.70
35
36
32.5
41
53.5
44
53.5
36.5
40
295
223
244
203
81
142
41
203
41
10.3
8.0
-8.3
4.3
6.2
2.2
---
5.13
3.89
4.25
3.54
1.42
2.47
0.71
3.54
0.71
50.5
50.5
295
259
14.9
13.1
5.13
4.52
33.5
35.5
32
565
529
459
18.9
18.8
14.7
9.85
9.22
8.00
Table 2.3: Results of Vapor Permeance Test Results [Straube, 2000]
The most remarkable result of the study was the influence of lime on stucco
mixes. Increasing the lime content of stucco mixes (maintaining the typical 3:1
ratio of aggregate to cementitious binders) caused a large increase in permeance
(Figure 2.2). Pure lime:sand stuccos were the most permeable tested. It is also
clear that pure cement:sand stuccos are quite vapor resistant, meeting the
definition of a vapor barrier in many cases.
Different coatings generated quite different results. The elastomeric and
siloxane had little effect on the vapor permeability of the cement samples. The
same two treatments appeared to reduce the permeability of the more
permeable 1:1:6 mix, although the permeability was still about 8 for both
products. The linseed oil had little effect on the permeance of either the 1:1:6
or 1:2:9 mixes. The latex paint reduced the permeance of the 1:1:6 mix to
about 200 metric perms (almost 4 US perms) as expected. The oil paint also
performed as expected, lowering the permeance of a 1:1:6 mix to around 40
BalancedSolutions.com
12
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
metric perms (0.6 US perms). Thus, oil paint can render a typical stucco a
vapor barrier by most code definitions.
The addition of the calcium stearate caused a reduction in permeance,
sometimes sizable, but the 1:1:6 stucco remained more permeable than the
cement.
Vapour Permeability (ng/Pa s m)
20
18.9
15.0
15
10
7.3
5
1.6
0
Cement:sand
1:1:6
1:2:9
Lime:sand
Cement:Lime:Sand Content
Figure 2.2 : Lime Content and Vapour Permeability [Straube, 2000 ]
Minke [2001] has produced several widely respected books on earth building, as
well as conducting and assembling technical information from around Europe.
His vapor permeability results are summarized in Table 2.4. His results
BalancedSolutions.com
13
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
essentially match Straube’s work for the common lime:sand stucco tested, but
offer also offer values fo earth plasters, and earth-straw mixtues.
Permeability
Permeance
Permeability
for 38 mm/1.5 in
Material Description
Clay soil
Silty soil
Sandy soil
Strawclay (1250 kg/m3)
Strawclay (950 kg/m3)
Strawclay (750 kg/m3)
Strawclay (450 kg/m3)
Clay earth plaster
Silty earth plaster
Cowdung-earth-lime plaster (12/4/3/20)
Lime Plaster
Lime-Casein-plaster (10:1)
Lime-linseed oil-Plaster (20:1)
ng/Pa s m
ng/Pa s m
25.7
31.0
24.8
41.3
62.0
64.1
82.7
23.3
19.1
23.5
16.9
14.3
13.2
675
816
653
1088
1632
1688
2175
612
502
620
445
377
347
2
US Perm-inch
17.6
21.3
17.0
28.4
42.6
44.1
56.8
16.0
13.1
16.2
11.6
9.8
9.1
Table 2.4: Vapor Permeability Values of Soil and Soil-straw [Minke]
2.2.1
Moisture Storage
The Institute for Research in Construction / National Research Council of
Canada (IRC/NRCC) has recently completed a campaign of building material
property testing, including sorption isotherms. Some of this data is plotted in
Figure 2.3 for mortar, cement stucco, concrete, and for comparison, spruce
wood.
BalancedSolutions.com
14
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
10%
Spruce
9%
Mortar
Concrete
Moisture Content (M%)
8%
Stucco
7%
6%
5%
4%
3%
2%
1%
0%
0%
10%
20%
30%
40%
50%
60%
Relative Humidity (%)
70%
80%
90%
100%
Figure 2.3: Representative Values of Sorption Isotherms for Cementbased Concrete, Mortar, and Stucco
2.2.2
Water Uptake
The results of Straube’s water absorption coefficient testing on the test samples
already described above are shown in Table 2.5. Increasing the lime content of
the stucco mix resulted in increased water absorption. The siloxane and
elastomeric coatings dramatically reduced water absorption, with the siloxane
being especially effective. Linseed oil, of the type and rate applied, was not
very effective.
Minke [2001] found that various silanes and siloxanes applied to earth plasters
were very effective at reducing water absorption. The siloxanes performed best
with no increase in vapor resistance. His results also showed that a linseed oil
coating, applied at 400 g/m2 (about a pint per square yard) was also effective at
reducing water absorption, but did add a significant amount of vapor resistance
(about 128 metric perms, or 2 US perms).
BalancedSolutions.com
15
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Suction (kg/(m2 s1/2)
Sample
Cement
1:3 datum
0.0378
1:3 elastomeric
0.0085
1:3 siloxane
0.0004
Cement:Lime
1:1:6 datum
0.0917
1:1:6 linseed
0.0665
1:1:6 elastomeric
0.0146
1:1:6 siloxane
0.0006
1:1:6 calcium stearate
0.1005
1:1:6 calcium stearate
0.0833
1:1:6 calcium stearate
0.0934
1:1:6 latex paint
0.0197
1:1:6 oil paint
0.0140
Cement:Lime
1:2:9 datum
0.1100
1:2:9 linseed
0.1052
Lime
1:3 Datum
0.1273
1:3 Datum
0.1725
1:3 Quicklime
0.1608
Table 2.5: Water Absorption Coefficient Results [Straube 2000]
Suction (kg/(m2 s1/2)
Material
0.152
Earth plaster
Earth plaster w/siloxane (BS15 Wacker)
Earth plaster w/2 coasts lime: casein (1:8)
Strawclay (1150 kg/m3)
Strawclay (450 kg/m3)
0.00170
0.0117
0.052
0.040
Table 2.6: Water Absorption Coefficient Results [Minke 2001]
BalancedSolutions.com
16
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
3 Test Program
The test program involved:
1. casting a range of different stucco mixes,
2. applying various coatings (paints and water repellent coatings) to some of
the samples
3. conducting vapour permeance tests under a realistic relative humidity
gradient
4. conducting water uptake (capillary absorption tests) tests.
The test procedures, apparatus, and samples will be described in greater detail
below.
3.1
Mix Designs and Sample Preparation
The following mixes were chosen by EBNet and produced by Vital Systems.
The majority of the samples were earth and lime based plasters. This is due to
the fact that significant data already exists for cement based stuccos.
The samples were in two groups. The first group of six test mixes was the
official sample set, of which triplicates were made. These are described, based
on the information sent with the samples and received from Tim Owen
Kennedy, in Table 3.1. The measured density is also included to allow for a
quantitative comparison.
The lime plaster appeared to be poorly consolidated, and one of the three
samples was broken on delivery.
A wide range of additional samples were sent, with different mix additives and
coatings. These samples, of which only one each were provided, are
summarized in Table 3.2.
BalancedSolutions.com
17
Moisture Properties of Plaster and Stucco for Strawbale Buildings
Mix #
EBNet
Avg. Density [kg/m3]
Description
1
Portland cement plaster (1:0.2:3)
1,997
2
Cement lime plaster (1:1:6)
1,942
3
Lime plaster (1:3)
1,748
4
Earth Plaster -1
1,531
5
Earth Plaster -2
1,759
6
Earth Plaster -3
1,844
Table 3.1: Plaster Test Samples (triplicate)
The samples were shipped from California in carefully padded boxes, with each
sample surrounded in a plywood case (Figure 3.1).
Label
Description
Density
[kg/m3]
1/2 D
Mix D with Sodium Silicate 100%
1,643
3-4 D
3/4" Mix D with ¼" Lime Plaster & 3 Coats of Lime
Wash
1,419
D
Mix D with Sodium Silicate 50%
1,698
1-1/4 D
Mix D with Lime Wash (5 Coats)
1,408
OIL ON
2% Raw Linseed Oil in Mix D
1,643
Mix D with Wheat Stabilized Interior Clay Paint Finish
1,666
L1
10% Lime by Volume in Clay Plaster Mix
1,621
L2
50% Lime by Volume in Clay Plaster Mix
1,741
ALIZ
Table 3.2: Other Plaster Samples Tested (one each)
BalancedSolutions.com
18
Moisture Properties of Plaster and Stucco for Strawbale Buildings
Figure 3.1: Samples, as received
BalancedSolutions.com
19
EBNet
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
4 Vapor Permeability
Vapor permeability is important for the assessment of strawbale wall drying.
Each of the samples described in Section 3 was tested for permeance. This
section describes the test equipment, protocol, results and interpretation.
4.1
Vapor Permeance Test Protocol
ASTM E96 is used as a basis but some modifications were required to
accommodate the materials. Instead of a wet-cup test (100%-50%), we
employed conditions of 75-100%RH. These later conditions more accurately
mimic the condition of interest, namely that of drying wet material (at
100%RH) to outdoor air in moderately humid conditions (75%).
4.2
Test Equipment and Setup
Samples were placed horizontally over a sealed, vapor impermeable container
of plastic (Figure 4.1). They were sealed around their vertical edges and to the
container in a vapor tight manner using aluminum tape and paraffin wax. The
area of sample exposed to the exterior was carefully taped off to an area of 125
x 125 mm and measured to an accuracy of better than 1%. The area of sample
exposed to the interior of the container was kept the same as that exposed to
the exterior by using a machined PVC plate. The two areas were essentially
perpendicular (within ±2 degrees or ±1.5 mm, whichever is less restrictive).
To reduce the initial weight, EPS foam inserts were used to displace some
water in the deep plastic reservoirs. A plastic grill about 12mm ( ½”) deep with
grids spaced at about 15 mm (5/8”) was used to prevent the foam from
floating up and to control sloshing during measurement. Sloshing of water can
cause contact with the sample and result in high readings.
An electronic Sartorius balance capable of accurately measuring up to 12 kg
with an accuracy of ±0.01 g was used for all of the mass measurements.
The samples were placed in an insulated controlled temperature and humidity
chamber. The humidity was controlled using a saturated salt solution, air was
circulated using fans, and a thermostat controlled an electric heater to maintain
the chamber temperature at 25 C (77 F) with a control of better than +/- 1 C
(+/- 1.8F).
BalancedSolutions.com
20
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
RH 2
Vapor tight
seal
Sample
Saturated salt
or water
solution
RH 1
Vapor and air
tight container
Figure 4.1: Test Apparatus Schematic for Measuring Vapor Permeance
Figure 4.2: Photograph of Sample Assembly
BalancedSolutions.com
21
Moisture Properties of Plaster and Stucco for Strawbale Buildings
Figure 4.3: Temperature and Humidity Controlled Chamber
BalancedSolutions.com
22
EBNet
Moisture Properties of Plaster and Stucco for Strawbale Buildings
4.3
EBNet
Procedure
The sample-container assemblages were weighed before being placed in the
constant temperature/humidity chamber. The weight of the container-sample
assembly was then weighed at equally spaced intervals (typically a few weeks).
Tests can require several months.
When the rate of weight change over at least three intervals have the same rate
(typically within 2%) equilibrium can be assumed to have taken place, and the
permeance of the sample can be calculated (Figure 4.4). We chose to plot the
data, and stop the tests when the slope of the graph (permeance) was consistent
over several measurement periods.
Weight loss ( since start)
30
Constant weight
loss period
25
20
15
10
5
0
-5
0
2
4
6
8
Time (interval)
Figure 4.4: Example Vapor Permeance Test Data
4.4
Interpretation
The vapor permeance and permeability values can be calculated from the
measured, steady-state weight loss (or gain). The permeance of the sample is
calculated from:
BalancedSolutions.com
23
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Permeance in ng/Pa s m2 = (weight loss in nanograms†) / [( duration of
time interval in seconds) x (sample area in m2) x (average vapour
pressure difference in Pa)].
And permeability is calculated as:
Permeability in ng / Pa s m = permeance / avg sample thickness in m.
4.5
Results
The results for the two series of plaster samples are summarized in Table 4.1
and Table 4.2. The results are plotted in Appendix A.
Mix
#
Description
Permeance
(ng/Pa m2 s )
Permeability
(ng/Pa m s )
US Perms
1
Portland cement
plaster (1:0.2:3)
355
13.7
6.2
2
Cement lime plaster
(1:1:6)
514
19.0
9.0
3
Lime plaster (1:3)
804
30.1
14.0
4
Earth Plaster - 1
1,259
45.7
21.9
5
Earth Plaster -2
1,133
41.2
19.7
6
Earth Plaster -3
1,073
40.1
18.7
Table 4.1: Vapor Permeance and Permeability (avg of triplicates)
Permeance for 38 +/- 1 mm (1.5” thick) samples
†
one nanogram equals one billionth of a gram, e.g., 1 x10-9 grams.
BalancedSolutions.com
24
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Permeance
(ng/Pa m2 s )
Permeability
(ng/Pa m s )
Permeance
(US Perms)
1,408
52.1
24.5
919
34.0
16.0
Mix D with Sodium
Silicate 50%
1,162
41.8
20.3
1-1/4
D
Mix D with Lime Wash
(5 Coats)
1,102
40.8
19.2
OIL
ON
2% Raw Linseed Oil in
Mix D
872
32.3
15.2
1,201
44.5
20.9
ALIZ
Mix D with Wheat
Stabilized Interior Clay
Paint Finish
L1
10% Lime by Volume in
Clay Plaster Mix
1,097
41.7
19.1
L2
50% Lime by Volume in
Clay Plaster Mix
1,092
40.4
19.0
Label Description
1/2 D
Mix D with Sodium
Silicate 100%
3-4 D
3/4" Mix D with 1/4"
Lime Plaster & 3 Coats
of Lime Wash
D
Table 4.2: Vapor Permeance of Other Plaster Samples (one each)
Permeance for 38 +/- 1 mm (1.5” thick) samples
4.6
Discussion
Several interesting results can be seen from the tabulated data. The EBNet
cement stucco sample was much more permeable than values for pure 1:3
cement stuccos in the literature (permeability of 13.7 versus 1.7 by Straube).
This is almost certainly due to the fact that the EBNet sample contained 0.2
parts lime or masonry cement. While this may be common practice, it does
result in different results because of the powerful vapor diffusion enhancement
effect of lime additives.
The 1:1:6 plasters were more comparable, with an EBNet permeability of 19
versus 10 in the earlier Straube study. The results for the lime plaster also show
BalancedSolutions.com
25
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
an increase in permeance, with the EBNet sample returning a value of 30,
whereas Straube and Minke reported results of 15 to 19 and 17 respectively. It
is possible that the samples were of a lower density, or where applied
differently (in a casting box instead of on a bale), or where cured differently.
All of these factors are known to play a significant role.
The earth plasters tested are the most permeable samples we have tested. They
appear to have a decreasing permeability with increasing density. This is
expected and the data is consistent. In any event, the range of permeance is
low, with the nine 38 mm (1.5 inch) plaster samples with an average density
1700 kg/m3 of exhibiting a permeance of 1017 to 1290 (17.8 to 22.5 US
Perms). These results match those of Minke’s more extensive testing for
strawclay mixtures. It is worth noting that this level of vapor permeance is
about the same or greater than many housewraps and building paper products.
Hence, as suspected, earth plasters clearly have the ability to allow fast drying.
The second series of singular samples were all based on earth plaster. The
results were all grouped tightly together. The D mix with 100% sodium silicate
may have been an aberration, since this showed a very high permeance which
slowly increased during the test. The vapor permeance of the sample with
linseed oil exhibited reduced vapor permeability of about 32 ng/Pa s m, or
20% less than the average of the earth samples. The earth sample with the lime
plaster and lime wash was also slightly less permeable than the untreated earth
plaster. The sample with 5 coats of lime wash was essentially as permeable as
the bare earth, although it is likely some small reduction occurred that was not
large enough to be measurable.
The addition of sodium silicate did not appear to impact the vapor permeance
noticeably, although a slight reduction was noted.
Importantly, the addition of 10% and 50% lime to the clay plaster mix did not
reduce the permeance significantly.
BalancedSolutions.com
26
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
5 Water Uptake Testing
As described earlier, water uptake testing is very useful for assessing the ease
with which material will allow liquid water movement.
5.1
Test Protocol
The test protocol followed the EuroNorm TC 89/WG10 N95 and German
DIN 52617.
5.2
Test Equipment and Setup
Samples were placed horizontally in a water tight container on two supports
(Figure 5.1). To prevent the surface of the earth plaster from becoming
dissolved in the water, the samples were supported by a plastic grill about
12mm ( ½”) deep with grids spaced at about 15 mm (5/8”). This grill
supported a fine plastic screen under a filter paper. This apparatus allowed
water to wick easily through while giving good support to the sample. This
approach was also used by Hansen et al [2001] in their testing of natural
materials. The lid of the container was covered to prevent excess evaporation.
An electronic Sartorius balance capable of accurately measuring up to 12 kg
with an accuracy of ±0.01 g was used for all of the mass measurements.
Room Conditions
Container
Water
Supports
Sample
Figure 5.1: Test Apparatus for Measuring Water Absorption
BalancedSolutions.com
27
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Figure 5.2: Sample preparation for water absorption test
Figure 5.3: Plaster Samples in test chamber (note grid and filter cloth)
BalancedSolutions.com
28
Moisture Properties of Plaster and Stucco for Strawbale Buildings
5.3
EBNet
Procedure
Samples were dried until in equilibrium with laboratory conditions (50%RH).
They were weighed, and then placed in contact with water to a depth of 1 to 2
mm (1/16"). The specimen area (of the face to be tested) and thickness was
also measured and recorded. The area of the sample was measured to an
accuracy of 1% of total dimension or better. The weight gain was measured at
several points over a 24 hour period (typically 1, 2, 4, 8, and 24 hrs).
5.4
Interpretation
The total weight gain (measured weight less dry weight) per unit area is plotted
versus the square root of time. The resulting plot usually exhibits a straight line,
and the water absorption coefficient is defined as the slope of this line in units
of kg/(m2 hr1/2) or kg/(m2 s1/2). If the line exhibits an initial slope that is
different from the final slope, the initial straight portion is used. If there is no
significant change in slope, the total water uptake at 24 hours is used to define
the water absorption coefficient, A.
Weight gain ( g since start)
30
25
20
Slope = water
absorption
coefficient
15
10
5
0
0
2
4
6
Square Root of Time
Figure 5.4: Example Water Uptake Test Data
BalancedSolutions.com
29
8
Moisture Properties of Plaster and Stucco for Strawbale Buildings
5.5
EBNet
Results
The water absorption coefficients for all of the samples are summarized in
Table 5.1 and Table 5.2 below. The results are also plotted in Appendix A.
It can be seen that the curves do not always exhibit a well defined slope as is
typical of most porous materials. This is especially true of some of the lime
and cement samples. This is likely because of the different surface treatments,
e.g., a trowel smooth surface has a low absorption coefficient because the
surface has closed cells.
Mix #
Water Absorption (kg/m2s1/2)
Description
1
Portland cement plaster (1:0.2:3)
0.059
2
Cement lime plaster (1:1:6)
0.083
3
Lime plaster (1:3)
0.164
4
Earth Plaster - 1
0.075
5
Earth Plaster -2
0.068
6
Earth Plaster -3
0.067
Table 5.1: Water Absorption Coefficients (avg of triplicates)
It was observed that the earth plaster samples developed a wet, muddy, skin
soon after contacting the water (within 30 minutes). The samples were
remarkably tolerant of wetting however, and the effort taken with the grid and
mesh was probably not necessary. The lime washed earth plasters remained
firm even after 24 hours in contact with water.
BalancedSolutions.com
30
Moisture Properties of Plaster and Stucco for Strawbale Buildings
Label
Description
EBNet
Water Absorption
(kg/m2s1/2)
1/2 D
Mix D with Sodium Silicate 100%
0.061
3/4 D
3/4" Mix D w/ 1/4" Lime Plaster & 3 Coats of
Lime Wash
0.046
D
Mix D with Sodium Silicate 50%
0.052
1-1/4
D
Mix D with Lime Wash (5 Coats)
0.047
OIL
ON
2% Raw Linseed Oil in Mix D
0.066
ALIZ
Mix D with Wheat Stabilized Interior Clay
Paint Finish
0.087
L1
10% Lime by Volume in Clay Plaster Mix
0.106
L2
50% Lime by Volume in Clay Plaster Mix
0.092
Table 5.2: Water Absorption of other Plaster Samples (one each)
5.6
Discussion
The results of the uptake tests were not very consistent or repeatable in the
case of the lime and cement stuccos. The earth plasters were remarkably
consistent, exhibiting a coefficient of variation of only 3 to 6%. The earth
plaster samples were remarkably consistent, and low absorption. Minke found
his earth plasters to be twice as absorptive (0.152) although this range of
material property must be considered normal in earthen materials. There was a
slight trend toward lower absorption with increasing earth plaster density.
The results covered a relatively narrow range. The cement, and cement : lime
stuccos responded in a very similar manner as the earth plasters. The lime
plaster samples were by far the most absorbent, although the rough and poorly
consolidated state of the samples should be borne in mind.
Sample 2-1 was tested with the cast side down, i.e., the face that was cast
against the wood was placed in contact with the water. In all other cases, the
face finished with a trowel was placed in contact with the water. This
BalancedSolutions.com
31
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
difference may be the reason that the Sample 2-1 exhibited very high water
absorption values. Sample 1-1 also exhibited aberrant behavior because the
surface finish was quite different.
In general, none of the coatings reduce water absorption to the remarkable
degree that siloxane did in both Straube and Minke’s previous test. The best
results were achieved by samples with coats of lime wash (which also exhibited
high vapor permeance).
The addition of lime to the earth plasters seemed to increase the water
absorption. Perhaps the addition of several coats of lime wash would reduce
the absorption.
Although we sealed around the edges of the samples with a poured in place hot
wax seal, water did appear to wick preferentially up along this edge (Figure 5.5).
This could be due to the nature of the sample preparation (cast in a wood
mold) or shrinkage and swelling at the edge seal area.
Figure 5.5: Water wicking at edges
BalancedSolutions.com
32
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
6 Conclusions
Based on the test data and literature review, several conclusions can be drawn:
1. A 450 mm (18”) thick strawbale should have a vapor permeance of
approximately 110 to 220 ng/ Pa•s•m2 (2 to 4 US perms).
2. Cement:sand stuccos are relatively vapour impermeable. In fact a 38 mm
(1.5”) thick cement : sand stucco may act as a vapor barrier (i.e., have a
permeance of less than 1 US Perm).
3. The addition of lime to a cement stucco mix increases permeance. As the
proportion of lime is increased, the permeance increases. Pure lime:sand
stuccos are very vapor permeable. The permeance of a 38 mm (1.5”) thick
cement : sand stucco can be increased to 5 or 10 US Perms by replacing half
the cement with lime and to 15 to 30 US Perms by using a pure lime : sand
stucco. The addition of even a small amount of lime (0.2 parts) may
increase the permeance of cement stucco dramatically (e.g.,from under 1 to
3 to 6 US Perms).
4. Earth plasters are generally more permeable than even lime plasters. The
addition of straw increases the permeability further. A 38 mm (1.5”) thick
earth plaster can have a permeance of over 1200 metric perms (over 20 US
Perms), in the same order as building papers and housewraps.
5. Applying an oil paint to a moderately permeable 1:1:6 stucco will provide a
permeance of less than 60 metric perms (1 US perms) and thus meet the
code requirements of a vapour barrier.
6. Earth plasters were not found to have significantly different water
absorption than cement and lime stuccos. The earth plasters, regardless of
density and straw content, resisted 24 hour of constant wetting easily,
although the topmost 1/8” of surface became quite “muddy”. In a real
rainstorm this behavior may cause erosion.
7. Lime washes appear to be somewhat useful for reducing water absorption
while not reducing vapor permeance. The lime wash over earth plaster did
not dramatically lower water absorption but will increase the mechanical
strength of the plaster after wetting, i.e., they will increase the resistance to
rain erosion.
8. Based on Minke’s and Straube’s earlier tests, siloxane appears to have little
or no effect on the vapor permeance of cement, cement:lime, lime, and
BalancedSolutions.com
33
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
earth plasters while almost eliminating water absorption. The use of
siloxane can be recommended based on these earlier tests.
9. Sodium silicate did not seem to have much impact on water uptake or vapor
permeance. This additive may hold earth plaster together, or increase its
erosion resistance, but as tested it had no noticeable impact on moisture
properties.
10. Linseed oil at 2% in an earth plaster mix is not a very effective water
repellent and does act to restrict vapor permeance somewhat. It may add
some strength to an earth plaster in the wet state. Heavy applications of
linseed oil to the surface of finished earth plaster will, based on Minke’s
tests, reduce the water absorption to almost zero, but will markedly decrease
vapor permeance.
11. The test methods described here appear to provide repeatable results, and in
general compare well to previous tests on different samples by both the
same (Straube) and different researchers (Minke).
BalancedSolutions.com
34
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
7 Acknowledgements
Most of the experimental test work was conducted by Frank McCarthy, who
deserves thanks for the care he took in the work. Patrick Roppel, Randy van
Straaten, and Chris Schumacher all helped during the development of the test
program and in the construction of the test apparatus. Tim Owen Kennedy and
the Vital Systems team produced the samples and made sure they were safely
delivered.
BalancedSolutions.com
35
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
8 References
Andersen, Birte Møller and Jørgen Munch-Andersen, Halmballer og muslinger som
isoleringsmaterialer, Danish Building Research Institute, June 2001.
Kurt K. Hansen, Ph.D. Carsten Rode, Ph.D. Ernst J. de Place Hansen, Ph.D.
Tim Padfield, Ph.D. Finn Kristiansen, “Experimental Investigation of the
Hygrothermal Performance of Insulation Materials”, Proc. Of Thermal Performance
of Exterior Envelopes of Buildings 8, Clearwater Beach, 2001.
Lamond, W.J., and Graham, R. ,“The Relationship Between the Equilibrium
Moisture Content of Grass Mixtures and the Temperature and Humidity of the
Air”, Journal of Agricultual Engineering Resources, 1993, pp. 327-335.
Minke,G., Das neue Lehmbau-Handbuch, 5th edition, Oekobuch, Freiburg, 2001.
Padfield, Tim. The role of absorbent building materials in moderating changes of relative
humidity. Ph.D. thesis, The Technical University of Denmark, Department of
Structural Engineering and Materials, October 1998, pp.161.
Straube, J.F. Moisture Properties of Plaster and Stucco for Strawbale Buildings, Report
for Canada Mortgage and Housing Corporation, June 2000.
BalancedSolutions.com
36
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Appendix A
Sample Descriptions and Raw Data
Sample
1-1
1-2
1-3
2-2
2-3
3-1
3-2
3-3
4-1
4-2
4-3
5-1
5-2
5-3
6-1
6-2
6-3
1/2 D
3/4 D
D
1-1/4 D
OILIN
ALIZ
L1
L2
Height
(mm)
40
38
38
38
36
Sample
38
37
37
36
36
36
37
36
38
37
37
37
37
36
37
37
37
38
37
BalancedSolutions.com
Width
(mm)
152
148
151
147
153
broken
148
153
149
146
147
145
148
148
150
149
146
149
155
151
151
149
150
150
150
Depth
(mm)
153
152
152
151
152
on
153
152
148
145
149
152
148
150
150
149
150
147
154
146
152
152
148
150
146
37
Volume
(mm3)
930,240
854,848
872,176
843,486
837,216
arrival
860,472
860,472
815,924
762,120
788,508
793,440
810,448
799,200
855,000
821,437
810,300
810,411
883,190
793,656
849,224
837,976
821,400
855,000
810,300
Weight
(g)
1,810.36
1,732.97
1,758.86
1,643.46
1,619.67
Density
(kg/m3)
1,946
2,027
2,017
1,948
1,935
1,524.44
1,483.75
1,215.27
1,184.13
1,221.26
1,377.92
1,417.08
1,431.89
1,509.20
1,561.19
1,512.40
1,331.83
1,252.82
1,347.26
1,196.03
1,376.46
1,368.39
1,386.28
1,410.74
1,772
1,724
1,489
1,554
1,549
1,737
1,749
1,792
1,765
1,901
1,866
1,643
1,419
1,698
1,408
1,643
1,666
1,621
1,741
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Sample 1 - Vapour Diffusion Test
100%RH - 75% RH at 25 C
30
Sample 1-1
Sample 1-2
25
Sample 1-3
Water Loss (Grams)
20
15
10
5
0
0
100
200
300
400
-5
Time (Hours)
Balanced Solutions.com
38
500
600
700
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Sample 2 - Vapour Diffusion Test
100%RH - 75% RH at 25 C
30
Sample 2-1
Sample 2-2
25
Sample 2-3
Water Loss (Grams)
20
15
10
5
0
0
100
200
300
400
-5
Time (Hours)
BalancedSolutions.com
39
500
600
700
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Sample 3 - Vapour Diffusion Test
100%RH - 75% RH at 25 C
30
Sample 3-2
Sample 3-3
25
Water Loss (Grams)
20
15
10
5
0
0
50
100
150
200
-5
Time (Hours)
BalancedSolutions.com
40
250
300
350
400
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Sample 4 - Vapour Diffusion Test
100%RH - 75% RH at 25 C
30
Sample 4-1
Sample 4-2
25
Sample 4-3
Water Loss (Grams)
20
15
10
5
0
0
100
200
300
400
-5
Time (Hours)
BalancedSolutions.com
41
500
600
700
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Sample 5 - Vapour Diffusion Test
100%RH - 75% RH at 25 C
30
Sample 5-1
Sample 5-2
25
Sample 5-3
Water Loss (Grams)
20
15
10
5
0
0
50
100
150
200
-5
Time (Hours)
BalancedSolutions.com
42
250
300
350
400
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Sample 6 - Vapour Diffusion Test
100%RH - 75% RH at 25 C
30
Sample 6-1
Sample 6-2
25
Sample 6-3
Water Loss (Grams)
20
15
10
5
0
0
50
100
150
200
250
-5
Time (Hours)
BalancedSolutions.com
43
300
350
400
450
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Other Samples - Vapour Diffusion Test
100%RH - 75% RH at 25 C
30
L1
L2
25
DILIN
ALIZ
1-1/4 D
Water Loss (Grams)
20
D
3/4 D
15
1/2 D
10
5
0
0
50
100
150
200
250
-5
Time (Hours)
BalancedSolutions.com
44
300
350
400
450
500
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Absorption Testing - Mix 1
175
1-1
150
1-2
1-3
Weight Gain (g)
125
100
75
50
25
0
-
1
2
3
Square Root of Time (hours)
BalancedSolutions.com
45
4
1/2
5
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Absorption Testing - Mix 2
175
2-1
2-2
2-3
150
Weight Gain (g)
125
100
75
50
25
0
-
1
2
3
Square Root of Time (hours)
BalancedSolutions.com
46
4
1/2
5
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Absorption Testing - Mix 3
175
150
3-2
3-3
Weight Gain (g)
125
100
75
50
25
0
-
1
2
3
Square Root of Time (hours)
BalancedSolutions.com
47
4
1/2
5
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Absorption Testing - Mix 4
300
4-1
4-2
250
4-3
Weight Gain (g)
200
150
100
50
0
-
1
2
3
Square Root of Time (hours)
BalancedSolutions.com
48
4
1/2
5
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Absorption Testing - Mix 5
300
5-1
5-2
250
5-3
Weight Gain (g)
200
150
100
50
0
-
1
2
3
Square Root of Time (hours)
BalancedSolutions.com
49
4
1/2
5
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Absorption Testing - Mix 6
300
6-1
250
6-2
6-3
Weight Gain (g)
200
150
100
50
0
-
1
2
3
Square Root of Time (hours)
BalancedSolutions.com
50
4
1/2
5
Moisture Properties of Plaster and Stucco for Strawbale Buildings
EBNet
Absorption Testing - Other samples
275
1/2 D
250
3/4 D
D
225
1-1/4 D
OIL IN
200
Weight Gain (g)
ALIZ
175
L1
L2
150
125
100
75
50
25
0
-
1
2
3
Square Root of Time (hours)
BalancedSolutions.com
51
4
1/2
5
Moisture Properties of Plaster and Stucco for Strawbale Buildings
BalancedSolutions.com
52
EBNet
EBNet
View publication stats
Moisture Properties of Plaster and Stucco for Strawbale Buildings
BalancedSolutions.com
53