In this paper, the thermoluminescence (TL) dosimetric characteristics under beta-ray, x-ray and gamma-ray excitations of powder and pellet Mn-doped lithium tetraborates (LTB) which were produced by solution combustion synthesis technique... more
    • by  and +4
    •   4  
      Thermoluminescence DosimetrySolution Combustion SynthesisThermoluminescenceThermoluminescent Materials
The behavior of Ge doped silica, SiO2 Flat Fibers (FF) irradiated with 2.5 MeV electron radiation at ultra-high dose (UHD) range, up to 1 MGy, has been investigated. The analyzed glow curves measured by the usage of the WinREMS software... more
    • by 
    •   7  
      Nuclear PhysicsRadiation DosimetryNuclear Medicine PhysicsMedical Physics
The supralinearity of GFF and TLD-100 was highly dependent on the UHD. The maximum supralinearity f(D)max of TLD-100, occurs around 10 kGy. TL kinetic model can be used to explain the glow peak behavior of doses o f(D)max. The... more
    • by 
    •   3  
      Radiation DosimetryThermoluminescence DosimetryThermoluminescent Materials
The basics of dosimetry and thermoluminescence are undertaken. The effect of annealing atmosphere is crucial for reproducible TL output and glow curves. Three annealing treatments were tested by Carrillo et al.* the adverse effect of an... more
    • by 
    •   5  
      Antennas & Radio Wave PropagationRadiation dosimetry (Physics)Thermoluminescence DosimetryThermoluminescent Materials
Many thermoluminescence dosimetry (TLD) materials exhibit a variation in read-out with light exposure (including both visible and UV radiation energy) which may cause problems in environmental dosimetry. The aim of the present study was... more
    • by 
    •   4  
      Radiation dosimetry (Physics)BleachingThermoluminescence DosimetryThermoluminescent Materials
Factors affecting the random and systematic error in calibrating three sets of 100 LiF:Mg,Ti thermoluminescent detector chips were investigated. The chips were held in a polymethyl methacrylate plate with 0.3 cm deep wells covered with a... more
    • by  and +1
    •   23  
      StatisticsApplied StatisticsRadiation safetyRadiation Health Physics
A method to generate depth-dose distributions due to beta radiation in LiF and soft tissue is proposed. In this method, the EGS4 Monte Carlo radiation transport code is initially used to generate a library of monoenergetic electron... more
    • by 
    •   8  
      Radiation safetyRadiation PhysicsRadiation DosimetryRadiation Protection
    • by 
    • Thermoluminescent Materials
This study examines the reproducibility of LiF:Mg,Ti pre-irradiation and post-irradiation fading rates. To test post-irradiation fading, 99 calibrated 3.2 × 3.2 × 0.9 mm3 LiF:Mg,Ti thermoluminescent dosimeters (TLDs) of dimensions were... more
    • by 
    •   28  
      PhysicsRadiation PhysicsRadiation DosimetryRadiation Protection
"La verificación de la dosis de radiación recibida por el área expuesta durante eltratamiento médico es esencial para la evaluación de cualquier régimen de radioterapia.Este trabajo describe las caracteríısticas termoluminiscentes (TL)de... more
    • by 
    •   21  
      Materials EngineeringChemical EngineeringPhysicsMaterials Science